6 720 646 148 - 11/2010 US/CA (en) For the user User’s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kW/100 kW This manual is available in the English and French language. This manual must be retained for future use.
Page 2
The operating manual is part of the documentation that is delivered to the instal- lation's operator. Go through the information in this manual with the owner/oper- ator and make sure that he or she is familiar with all the necessary operating instructions. http://www.buderus.net...
Setting the space heating water Identifying and resetting faults ..34 temperature "Burner ON" LED ....17 Other functions and economic heating http://www.buderus.net...
Page 4
These user's Instructions contain important Changes may be made following technical information for the safe and proper operation improvements! of Logamax plus GB162-L.B. 80kW/100kW condensing gas boilers. Updating of documentation If the information in this manual is not followed Please contact us if you have any suggestions exactly, a fire or explosion may result causing for improvements or corrections.
For your safety For your safety Logamax plus GB162 L.B. condensing gas Hazard definitions boilers are designed and built according to the DANGER latest technological advances and safety Indicates the presence of hazards that requirements. will cause severe personal injury, death The design is specifically focused on ease of or substantial property damage.
Buderus recommends a contract for annual personal injury or property damage. service and maintenance. – The condensate collection and disposal...
Page 7
– Use only your hand to turn the gas control to replace any part of the control system knob (fig. 4 on page 18). Never use tools. If and any gas control which has been under the knob will not turn by hand, don't try to water. http://www.buderus.net...
'3C'. Immediately call a trained service and damage to the heat exchanger. technician to inspect and reset the boiler. DO NOT treat the water with products such as pH-adjusting substances (chemical additives) and antifreeze or water softeners. http://www.buderus.net...
Lighting Instructions Lighting Instructions STOP! Read the chapter "For your safety" on page 5 before lighting the boiler. Follow the instructions to start up the boiler in “Starting up the boiler” on page 18 http://www.buderus.net...
5: Service Tool connector 9: Display 2: "Reset" button 6: LED "Burner operation" 10: DHW temperature knob 3: "Chimney sweep" button 7: LED "Heating system status" 11: LED "DHW status" 4: "Service" button 8: Space heating water temperature knob http://www.buderus.net...
Push on the control panel to open it (fig. 2) and get access to the controller. Switching ON and OFF Set the main switch on the BC10 to position "1" (ON) to switch ON the boiler and set it to "0" to switch the boiler OFF. http://www.buderus.net...
Setting the DHW temperature value Check the local code for the max. DHW temper- ature. Turn the "DHW temperature" rotary knob to set the desired temperature of the hot water in the DHW tank. http://www.buderus.net...
Page 13
Table 1 Settings of "DHW temperature" knob This function has been optimized for boilers with combined DHW heating (combi-units). The LED under the rotary knob lights if the DHW temperature is below the target value (heat request for DHW). http://www.buderus.net...
Operating the BC10 basic controller Setting the space heating water temperature Turn the "space heating water temperature" knob to set the upper limit value of the heater water for the heating operation. This limitation does not apply to DHW preparation. http://www.buderus.net...
Page 16
Table 3 Settings of "space heating water temperature" rotary knob The LED under the rotary knob lights when the heating system is switched ON and heat is requested. In summer mode the heating system is switched OFF (LED OFF). http://www.buderus.net...
The water in the boiler has reached the required temperature or there is no heat request. Table 4 LED indication Other functions and economic heating The functions described above are basic functions, carried out directly on the boiler using the BC10 basic controller. http://www.buderus.net...
¼ rotation in an counterclock- wise direction (fig. 3, pos. 1). The gas valve is open when it is in its vertical position. (fig. 3, Open the pump group isolating valves pos. 2 Fig. 3 Opening gas- and isolating valves http://www.buderus.net...
The maximum pressure in the heating system, measured directly at the boiler, must not exceed 51 psi (3.5 bar). Press the "Service" button (fig. 1, pos. 4) until the system pressure ("P22") is shown in the display (pos. 9). http://www.buderus.net...
has dropped below 15 psi (1.0 bar) according to paragraph “Fill the heating system” on page 20. Fill the heating system Remove the lower casing from the pump group (fig. 4). Fig. 4 Removing the lower casing http://www.buderus.net...
Page 21
Starting up the boiler Unscrew the sealing cap (fig. 5). Fig. 5 Removing cap from drain cock http://www.buderus.net...
Page 22
Fig. 6 Reading the pressure gauge NOTICE It is very important that the heating system is now purged, since all air will collect at the highest point of the heating system when the system is slowly filled with water. http://www.buderus.net...
The frost protection switches the boiler on at a flow temperature of 45 °F (7 °C) and off at a flow temper- ature of 59 °F (15 °C). The heating system itself is not protected against frost. http://www.buderus.net...
– Drain the heating system water from the lowest point of the heating system using the boiler filling and draining cock. The vent screw at the highest point of the heating system must then be open. http://www.buderus.net...
Basic controller BC10 Normal Operation menu [\/2/4| Shows currently measured space heating water temperature in °F. [p/2/2| Shows currently measured system pressure in psi. [-/h/\| Current display code. In this case: Operating phase: Boiler in heating mode. Table 5 Normal operation http://www.buderus.net...
– Space heating water temperature is as set on the BC10 basic controller. – The LED "Heating system status" lights. – DHW mode is possible during manual operation. [p/1.6} Shows currently measured system pressure in psi(pounds per square inch). Table 6 Manual operation http://www.buderus.net...
Page 27
[\/2/4}Shows currently measured space heating water temperature in °F. After a power interruption manual operation ends automatically. To end manually press and hold the button for more than 2 seconds until the dot disappears. Table 6 Manual operation (continued) http://www.buderus.net...
(section 4.1 on page 18). Settings menu To open the "Settings" menu: Press and hold the buttons for more than 2 seconds. [l/?/?| This shows the "Settings" menu is open. You can adjust the setting of this parameter. Table 7 Settings http://www.buderus.net...
Page 29
The minimum setting is [f/\/0| = 0 minutes. The factory default setting is 5 minutes. CAUTION Do not set the post purge time to less than 5 minutes. Higher: Increase the time with the button. The maximum setting is [f/6/0| = 60 minutes or [f/1/d| = 24 hours. Table 7 Settings (continued) http://www.buderus.net...
Page 30
NOTE: Setting [c/\/0| also switches OFF the hot water cylinder frost protection. After 5 seconds or after a power interruption the settings menu ends automatically. To end manually press the button. Any adjustments that you have made have been confirmed. Table 7 Settings (continued) http://www.buderus.net...
The boiler is in flue gas test or service mode. [-/h/\| The boiler is in heating mode. [-/h/} Any display code with a flashing dot in the bottom right-hand corner. The boiler is in manual operation mode. flashing Table 8 Display codes http://www.buderus.net...
Page 32
The boiler is standby. There is a current heat demand, but too much energy has been supplied. [0/h/\| The boiler is standby. There is no current heat demand. [0/l/\| Ignition phase. The gas valve is activated. Table 8 Display codes (continued) http://www.buderus.net...
Page 33
The system pressure is too low (less than 12 psi (0.8 bar)). [h/\/7| [h/\/7| The system pressure is too low (less than 12 psi (0.8 bar)). [p/?/?| The system pressure is too high (higher than 58 psi (4.0 bar)). [\/r/e| The boiler is resetting. Table 8 Display codes (continued) http://www.buderus.net...
If the fault cannot be reset: Write down the error message and contact your heating equipment service company. Make sure that the heating system is not damaged by frost (see the safety instructions in chapter “Shutting down the boiler” on page 24). http://www.buderus.net...