Summary of Contents for Buderus Logamax Plus GB162
Page 1
$SSOLFDWLRQV 0DQXDO *DV FRQGHQVLQJ ERLOHU CAUTION! Before putting the boiler into operation read this manual carefully. WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury, loss of life or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
Page 4
Fig. 1 Logamax plus GB162 with pump group /RJDPD[ SOXV *% DSSOLFDWLRQV PDQXDO _ 7HFKQLFDO VSHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW SULRU QRWLFH...
Page 5
Flue gas connection BC10 basic controller receptacle Air intake connection Installation option for room controller, e.g. RC35 Cover with user manual compartment Gas valve BC10 basic controller, can be expanded e.g. by the RC35 room controller Venturi Connection box (low-voltage and 120 VAC Burner cover connections) Supply temperature sensor...
Page 6
7KH ERLOHU LV GHOLYHUHG IDFWRU\DVVHPEOHG :KHQ UHFHLYLQJ WKH ERLOHU HQVXUH WKDW WKH SDFNDJLQJ LV LQWDFW &KHFN WKDW DOO LWHPV DUH LQFOXGHG LQ WKH GHOLYHU\ ¿J Pos. Parts Packaging l i o l l a Condensate trap with hose Technical documents set Supply and return union nuts with gasket rings...
Page 15
_ 11¼” 20¾” (288 mm) (525 mm) - Top view - 20¾” (525 mm) 22¾” (575 mm) - Front view - Fig. 11 Dimensions of cascade systems - 1 TL - Inline configuration Supply and return header Low loss header TR - Back-to-back configuration Enclosed welding flanges /RJDPD[ SOXV *% DSSOLFDWLRQV PDQXDO _ ...
Page 16
_ Length Cascade 39" (992 mm) Width system 7" (180 mm) 43¼" 1½" 22¾" 44¾" 1138 mm 1100 mm 38 mm 575 mm 64" 1½" 22¾" 65½" 1663 mm 1625 mm 38 mm 575 mm 84½" 1¾" 22¾" 86¼"...
Page 37
_ 10"- 0" MIN (250 mm - 0 mm MIN) 12” ( 300 mm) over maximum s now level or 24 ” (600 mm) whichever i s gre ater EXHAUST INTAKE EXHAUST INTAKE Fig. 32 Vertical venting system (room air only) Fig.
Page 53
_ MCM10 Front Panel Off: No power / internal error MCM10 On: Standard operation Off: Pump off On: Pump on Off: Switching contact not activated Blinking: System fault (example : system pressure too low or error in the heating appliance(s)) Off: No communication On: Communication between MCM10 and the previous MCM10.
Page 54
_ 120V 120V Printed PE N L PE N L PE N L NO C NC Circuit Board Input Mains Output Mains System Alarm / Error 120V 120V Supply Supply to Pump output 120V following PE N L PE N L PE N L NO C NC 0 ..
Page 71
_ RC 35 room control unit Wall Mounting Bracket 18AWG 18AWG Connection to EMS (boiler) * Connection * If room sensor is not used, leave factory to external installed jumper in place. room temperature sensor Ground yel/grn must not be used as a control line. /RJDPD[ SOXV *% DSSOLFDWLRQV PDQXDO _ 7HFKQLFDO VSHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW SULRU...
Page 73
_ 18AWG 120 V 60Hz 18AWG 18AWG 18AWG 14AWG, 5A 14AWG, 5A Main power supply 120 V 60Hz Valve actuator motor Ground yel/grn must not be used as a control line. run time: /RJDPD[ SOXV *% DSSOLFDWLRQV PDQXDO _ 7HFKQLFDO VSHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW SULRU...
Page 74
_ 14AWG 120 V 60Hz 14AWG, Max.5A 18AWG, 18AWG, 18AWG, Max.5A Max.5A Max.5A Main power zone low loss 120 V 60Hz header Ground yel/grn must not be used as a control line. /RJDPD[ SOXV *% DSSOLFDWLRQV PDQXDO _ 7HFKQLFDO VSHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW SULRU QRWLFH...
Page 75
_ 14AWG 120 V 60Hz 18AWG 18AWG 18AWG 18AWG 14AWG, Max. 1A Main power 120 V 60Hz tank Ground yel/grn /RJDPD[ SOXV *% DSSOLFDWLRQV PDQXDO _ 7HFKQLFDO VSHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW SULRU...