Panel Installation

DOOR PANEL INSTALLATION
Before attaching the door panel to the door, place two
screws in the center of each mounting position, just
enough that the slotted holes on the hinge side door panel
bracket will slide under the heads. These positioning
screws will support the door panel during installation and
adjustment. Refer to the illustration below.
Install the door panel by engaging the tabbed bracket to
the handle side of the door first and then sliding the hinge
side mounting bracket onto the positioning screws on the
hinge side of the door. The panel can be adjusted
up and down and side to side.
Once the door panel is in place and adjusted correctly,
attach the six remaining #10 x
side mounting bracket and install the magnetic decorative
caps as shown in the illustration below.
As the reveal between cabinets and the unit
decreases, the potential exists for severe finger
pinching if fingers are placed in the opening when
the door is closing.
Door panel installation.
1
/
" (6)
4
1
/
" screws to the hinge
2
PANEL BRACKET POSITIONING
The illustration below shows mounting hardware location
for door and drawer panels. Dimensions are based on a
1
/
" (3) reveal. A reveal of up to
8
panel dimensions need to be adjusted accordingly.
7
23
/
"
8
(606)
FOR 27" UNITS
7
32
/
"
8
(835)
FOR 36" UNITS
RH DOOR SWING
BACK OF PANEL
5
5
/
"
16
3
5
(135)
5
11
/
"
16
BACK OF PANEL
(287)
7
8
/
"
16
BACK OF PANEL
(214)
1
/
" (6) is possible, but
4
7
1
/
"
16
(37)
LH DOOR SWING
BACK OF PANEL
/
"
16
(132)
1
1
/
"
4
(32)
1
1
/
"
4
(32)
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

700tr700tf(i)700tc(i)700br700bf(i)700bc(i)

Table of Contents