Site Preparation
Anti-Tip Bracket Installation
INSTALL CONCRETE WEDGE ANCHORS:
3
1) Drill a
/
" (10) diameter hole any depth exceeding the
8
minimum embedment. Clean the hole or continue
drilling additional depth to accommodate drill fines.
Use a carbide drill bit manufactured within ANSI
B94.12-77.
2) Assemble the washer and nut flush with the end of
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is flush with
the surface material.
3) Expand the anchor by tightening the nut 3–5 turns past
hand-tight position or to 25 foot-pounds of torque.
Always wear safety glasses and use other necessary
protective devices or apparel when installing or
working with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use
in new concrete which has not had sufficient time to
cure. The use of core drills is not recommended to
drill holes for the anchors.
Unpacking and Moving
Uncrate the unit and inspect for any damages. Remove
the wood base and discard the shipping bolts that hold the
wood base to the bottom of the unit. Remove and discard
all packing materials.
Retract the front leveling legs all the way up to allow the
unit to be moved into position more easily. You will extend
the leveling legs when the unit is in its final position to
reduce the possibility of the unit tipping forward.
Use an appliance dolly to move the integrated unit near
the installation opening. Position the dolly at the side of
the unit to prevent damage to finished surfaces.