Integrated Installation

Position the Unit
Before moving the integrated unit into position,
protect any finished flooring, secure the door closed
and remove the drawers.
IMPORTANT NOTE: For drawer units, the top drawer has a
control cable that needs to be disconnected before
removing this drawer. Refer to the illustration below for
placement and how to disconnect this fitting.
The drawers should be placed aside until you are ready for
installation of the panels. Remove the decorative top and
side molding pieces and the kickplate/grille.
If two integrated units are installed closer than 2" (51) to
one another, it is necessary to use the Sub-Zero dual
installation heater kit (7007529). Refer to dual installations
on page 18 for additional information. The heater plate
from this kit must be attached to the left side exterior of
the right-hand unit before the units are slid into position.
Control cable—drawer unit.
IMPORTANT NOTE: If for any reason the integrated unit
has been laid on its back or side, you must allow the unit
to stand upright for a minimum of 24 hours before con-
necting power.
Plug the power cord into the electrical outlet. With power
applied to the unit, check for lighting and cooling. Press
the UNIT ON/OFF key pad on the control panel. Refer to
the illustrations below. Once you are satisfied that the unit
is operating properly, shut off power to the electrical outlet
at the circuit breaker and proceed.
Pre-level the unit before moving into position. This is to
allow the unit to engage the anti-tip bracket properly.
Slide the unit into position, making sure the anti-tip
bracket is engaged properly. Extend the front leveling legs
3
down approximately
/
16
ments easier.
When the integrated unit is installed, the anti-tip bracket
will be positioned just below the engaging bracket on the
unit. It is not necessary to raise the unit up so that it locks
into the anti-tip bracket, but the unit must be in alignment
with the anti-tip bracket.
The floor under the integrated unit must be at the same
level as the surrounding finished floor to allow the com-
pressor tray to be slid forward for service.
UNIT
ON/OFF
On/off key pad—tall unit.
subzero.com
" (5) to make additional adjust-
UNIT
ON/OFF
On/off key pad—drawer unit.
11