Table 1-6. System Messages (continued)
Message
PCIe Fatal Error
caused a system
reset: Slot X
Embedded
Bus#XX/Dev#XX/Fu
ncX
Please check the
system event log
for details
Plug & Play
Configuration
Error
Read fault
Requested sector
not found
Remote
configuration
update attempt
failed
Causes
PCI Express fatal errors
occurred during the previous
boot.
Error encountered in
initializing PCIe device;
faulty system board.
The operating system cannot
read from the hard drive or
USB device, the system could
not find a particular sector on
the disk, or the requested
sector is defective.
System unable to process
Remote Configuration
request.
Corrective Actions
Reseat the PCIe card in the
specified slot number (see
"Installing an Expansion
Card" on page 111). If the
problem persists, see
"Getting Help" on page 205.
Install the NVRAM_CLR
jumper and restart the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards" on page 186.
Replace the USB medium or
device. Ensure that the USB
or hard drive cables are
properly connected. See
"Troubleshooting a USB
Device" on page 165, or
"Troubleshooting a Hard
Drive" on page 181 for the
appropriate drive(s) installed
in your system.
Retry Remote Configuration.