Table 1-5. LCD Status Messages (continued)
Code
Text
E123C Planar LOM
PwrGd
E1310 RPM Fan ##
E1313 Fan
Redundancy
22
About Your System
Causes
Voltage regulator for the
integrated LOM has failed.
RPM of specified cooling
fan is out of acceptable
operating range.
The system is no longer fan-
redundant. Another fan
failure will put the system at
risk of over-heating.
Corrective Actions
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 205.
See "Troubleshooting
System Cooling
Problems" on page 172.
Check control panel LCD
for additional scrolling
messages (see
"Troubleshooting System
Cooling Problems" on
page 172).