Black Box V.32 9600 Async.
At the bridge
end:
At the user end:
Hayes 1200 Smartmodem
(for both 8-and 10-switch units)
At the bridge
end:
At the user end:
Racal Vadic Maxell 2400 VP (Hayes 2400 Compatible)
At the bridge
end:
At the user end:
C-2 Modem Configuration
Load the factory option set #1. Then make these changes:
Data Rate Menu: change to 9600 uncoded
–
–
Modem Parameters Menu: change to Forced Answer
–
DTE Parameters Menu:
– set DTR State to Responds to DTR Change
– set DSR State to DSR is Normal
– set CTS State to CTS is Normal
– set DCD State to DCD is Normal
Configure as at the bridge end except:
– Modem Parameters Menu: change to Normal Originate
Set all switches up.
Set switches 3 and 8 down, all others up.
Configure with a terminal or PC using the following sequence:
at&f&c1&d2&s1q1*f0&wz
Depress the ANS button. The red light should go ON.
Configure with a terminal or PC using the following sequence:
at&f&c1&d2&s1*f0&wz