Mounting And Adjusting Of The Draft Stabilasor - Effecta Komplett Installation & Service Manual

Pellet boiler
Table of Contents

Advertisement

Cleaning the rear housing and outer tube
After a period of heating up, there will be dust and soot from the burner´s
inner and outertube. These must be removed to avoid deterioration
in combustion and function. We recommend that the cleaning is
done after about 6 tons of pellets consumption. After the cover
is removed, start by loosening the
four wing nuts (1) wich are holding
the burner in place and then unload
according to description. Then pull
out the inner tube (2) and clean
from ash and soot. It is important
that the holes are not clogged with
soot, as these are essential to good
combustion. Then clean the outer
tube (3) from the soot and pellet
residues. Reassemble in reverse
order.
Mounting and adjusting of the draft stabiliser.
A draft stabiliser makes sure that a constant and stable draft is achieved. Also condensation
in the chimney is avoided.
Adjusting the balancing shaft
To adjust this shaft, loosen the two screws a bit and turn the shaft so that it is horisontally when
the hatch is closed. Then fasten the screws.
Adjusting the draft
By moving the counterweight along the balanceshaft, the draft needed to open the hatch is
adjusted. About 1Pa per 2mm.(fig.2) The hatch is preset at about 1Pa. A professional should
measure the draft and make the adjustments.
Functions
Tigex draft stabiliser opens the hatch just as much as needed depending on the current draft.
The draft varies a lot depending on the chimney, weather and also if the burner is running or
not. This means that the hatch can be open alot, a little or closed, depending the situation.