Examples Of Curves - Effecta Komplett Installation & Service Manual

Pellet boiler
Table of Contents

Advertisement

Example of curves
A too low heating curve will result in that the house will not have the correct indoor
temperature
Slope
80
70
60
50
40
30
20
-30
Adjustment
80
70
60
50
40
30
20
-30
-25
! If it is cold outdoors (cold winter) and the room temperature is too low. Increase the slope
with 1-2˚C
! If it is cold outdoors (cold winter) and the room temperature is too high. Decrease the
slope with 1-2˚C
! If it is warm outdoors (average autumn/spring) and the indoor temperature is too low.
Increase the adjustment with 1-2˚C
! If it is warm outdoors (average autumn/spring) and the indoor temperature is too high.
Decrease the adjustment with 1-2˚C
! Wait at least 24 hours between adjustments and changes due to slow response of heating.
Effecta AB Västra Rågdalsvägen 21 434 99 Kungsbacka Sweden +46-300 - 22320 info@effecta.se
The heating curve chosen in the software is the temperature
to the flow at -15˚C outdoor temperature. Therefore the flow
temperature will change with the outdoor temperature.
-25
-20
-15
-10
When a adjustment of 5˚C is done, the heating curve is
adjusted at all outdoor temperature with 5˚C.
-20
-15
-10
-5
0
5
Slope 50˚C, adjustment +5˚C
Slope 50˚C with no adjustment
-5
0
5
10
15
20
25
Outdoor temperature
10
15
20
25
Outdoor temperature
27

Advertisement

Table of Contents
loading

Table of Contents