Appendix C 24 Vac Wire Gauge And Transmission Distance - ALIBI ALI-IPZ5030T Installation Manual

Ali-ipz5030 series ip ptz camera
Table of Contents

Advertisement

APPENDIX C
24 Vac Wire Gauge and Transmission Distance
The following table shows the recommended maximum distance adopted for the different wire sizes when the 24 Vac voltage loss is
less than 10%. For the AC driven device, the maximum voltage loss rate allowable is 10%. For example, for a device with the rating
power of 80 VA which is installed 35 feet (10 m) from the transformer, the minimum wire gauge required is 0.8000 mm.
Table 1. Table of wire gauge standards
Distance: ft (m)
Power (VA)
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
APPENDIX C: 24 VAC WIRE GAUGE AND TRANSMISSION DISTANCE
0.8000
1.000
283 (86)
451 (137)
141 (42)
225 (68)
94 (28)
150 (45)
70 (21)
112 (34)
56 (17)
90 (27)
47 (14)
75 (22)
40 (12)
64 (19)
35 (10)
56 (17)
31 (9)
50 (15)
28 (8)
45 (13)
25 (7)
41 (12)
23 (7)
37 (11)
21 (6)
34 (10)
20 (6)
32 (9)
18 (5)
30 (9)
17 (5)
28 (8)
16 (4)
26 (7)
15 (4)
25 (7)
14 (4)
23 (7)
14 (4)
22 (6)
ALI-IPZ5030 Series IP PTZ Camera Installation Guide
Wire Gauge (mm)
1.250
716 (218)
358 (109)
238 (72)
179 (54)
143 (43)
119 (36)
102 (31)
89 (27)
79 (24)
71 (21)
65 (19)
59 (17)
55 (16)
51 (15)
47 (14)
44 (13)
42 (12)
39 (11)
37 (11)
35 (10)
2.000
1811 (551)
905 (275)
603 (183)
452 (137)
362 (110)
301 (91)
258 (78)
226 (68)
201 (61)
181 (55)
164 (49)
150 (45)
139 (42)
129 (39)
120 (36)
113 (34)
106 (32)
100 (30)
95 (28)
90 (27)
29