Belt, Platen Open - IBM 6400 Maintenance Information Manual

6400 series cabinet and pedestal models, line matrix printers
Hide thumbs Also See for 6400:
Table of Contents

Advertisement

Belt, Platen Open

Removal
1. Prepare the printer for maintenance (page 152).
2. Cabinet Model: Remove the paper guide assembly (page 229).
Pedestal Model: Remove the top cover assembly (page 204).
3. Remove the platen open belt cover by squeezing the top and bottom to
release the plastic tabs from the slots in the side plate. (See page 276,
Figure 51, item 24.)
4. Loosen (do not remove) the two motor mount screws (page 278, Figure
52, item 15).
5. Push the motor toward the front of the printer to loosen the platen open
belt.
6. Loosen the setscrew in the platen open motor pulley.
7. Remove the platen open belt by sliding the platen motor pulley off the
motor shaft and the belt off the platen open pulley.
Installation
1. Slide the platen open timing belt over the platen open pulley and the
motor pulley and tighten the 1/16 inch setscrew.
2. Slide the motor pulley onto the platen open motor shaft and tighten the
pulley setscrew.
Too much tension on the platen open belt can cause the platen gap to
change, which can lead to premature wear of the platen, damaged
hammer tips, and poor print quality.
3. Using a force gauge, apply 10 pounds (44.48 N) of tension to the motor
shaft by pushing in the direction away from the large platen pulley.
4. Reduce tension to 5 pounds (22.24 N) and torque the motor mount
screws to 11 ± 2 inch-pounds (1.24
5. Snap the platen open belt cover into the slots in the side plate.
6. Cabinet Model: Install the paper guide assembly (page 229).
Pedestal Model: Install the top cover assembly (page 204).
7. Return the printer to normal operation (page 153).
ATTENTION
±
0.23 N•m).

Belt, Platen Open

189

Hide quick links:

Advertisement

Table of Contents
loading