Reset Button - Altronix AL842ULADA Installation Manual

Nac power extender
Hide thumbs Also See for AL842ULADA:
Table of Contents

Advertisement

Fig. 2
unswitched 120VAC
power mains
(non-power limited)
line
ground
neutral
Green Lead
line
Fig. 2b
AC DELAY
These circuits are used to monitor
AC and Bat Fail and will cause a
simultaneous trouble condition
to the FACP's IN1 and IN2
(Non-Supervised)
AL842ULADA
Factory Installed
Board Interface
Optional Hookup Diagram:
Cable
AC DELAY
These circuits are used
to monitor AC and Bat Fail
and will cause
a simultaneous
trouble condition to the
FACP's IN1 and IN2
(Non-Supervised)
These circuits are used
to monitor AC and Bat Fail
a simultaneous
trouble condition to the
FACP's IN1 and IN2
(Non-Supervised)
NC "DRY2" C
-- RET2 +
NC "DRY1" C
Addressable
(See Typical Application Diagram for device hookup)
control module
trigger output
Power-Limited Outputs 2.5 amp per output max.
Non-Supervised
Supervised
NC "DRY2" C
-- RET2 +
-- RET1 +
Factory Installed
NC "DRY1" C
-- IN2 +
-- IN1 +
Board Interface
Cable
Factory Installed
Board Interface
Cable
OUT1
IN>OUT SYNC
STROBE SYNC
FAULT
INP2 INP1
TEMPORAL
INPUT SELECT
OUT2
IN>OUT SYNC
OUT1 OUT2 OUT3 OUT4
STROBE SYNC
TEMPORAL
INPUT SELECT
Magnetic
Door Holder
FAULT
INP2 INP1
OUT1 OUT2 OUT3 OUT4
+
--
4-wire Smoke
Detector
Fire
Alarm
Control
Magnetic
Panel
(FACP)
Door Holder
+
4-wire Smoke
Detector
Fire
Alarm
Control
Panel
(FACP)
and will cause
-- RET1 +
-- LOOP1 +
-- IN2 +
-- IN1 +
-- OUT1 +
Addressable
control module
(total = 8 amp)
trigger output
(Supervised)
Non-Supervised
-- LOOP1 +
-- LOOP2 +
-- LOOP3 +
-- LOOP4 +
-- AUX2 +
-- OUT1 +
-- OUT2 +
-- OUT3 +
-- OUT4 +
-- AUX1 +
Non-Supervised
Supervised
NC "DRY2" C
-- RET2 +
-- RET1 +
NC "DRY1" C
-- IN2 +
OUT3
OUT4
RESET
+ DC ---
OUT1
OUT3
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
OUT2
OUT4
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
+
--
4-wire Smoke
Detector
EOL Power
Supervision Relay
(Not Supplied)
EOL Resistor
from FACP
FAULT
INP2 INP1
OUT1 OUT2 OUT3 OUT4
Magnetic
Door Holder
--
+
4-wire Smoke
Detector
Fire
Alarm
Control
Panel
(FACP)
-- LOOP2 +
-- LOOP3 +
-- OUT2 +
-- OUT3 +
Fig. 2a
(See Typical Application Diagram for de
Power-Limited Outputs 2.5 amp per o
(total = 8 amp)
AC
(Supervised)
-- LOOP1 +
-- LOOP2 +
-- IN1 +
-- OUT1 +
-- OUT2 +
Fig. 2c
RESET
+ DC ---
Trouble Memory

Reset Button

OUT1
OUT3
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
OUT2
OUT4
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
+ DC ---
+
--
4-wire Smoke
Detector
--
+
4-wire Smoke
Detector
EOL Resistor
from FACP
-- LOOP4 +
-- A
-- OUT4 +
-- LOOP3 +
-- OUT3 +
RESET
Su
(
--
EOL R
from
- 7 -