Troubleshooting Without Error Messages; Initial Operation Problems - MUTOH ValueJet 1304 Service Manual

Hide thumbs Also See for ValueJet 1304:
Table of Contents

Advertisement

9 Troubleshooting

9.3 Troubleshooting Without Error Messages

This section describes the symptoms of errors without an error message as well as the check items and
recovery actions.
9.3.1

Initial Operation Problems

Table 9-7 Symptoms, Check Items and Actions for Initial Operation Problems
No.
Symptom
1
Machine power
cannot be turned ON
Rev.-01
CS9050, CS9150
Check item
1. Is operation panel
unit assembly cable
broken or shorted?
2. Panel unit assembly
may be damaged.
3. Inlet assembly may
be defective.
4. Power board
assembly may be
defective.
9-30
VJ-1304   Maintenance Manual
Action
Replace panel cable.
Replace panel unit
assembly.
Replace inlet assembly.
Replace power board
assembly.
Reference
"4.2.2
Removing
Operation
Panel Unit"
p.4-9
"4.2.2
Removing
Operation
Panel Unit"
p.4-9
"4.3.8
Replacing
Inlet
Assembly"
p.4-37
"4.3.6
Replacing
Power Board
Assembly"
p.4-31

Advertisement

Table of Contents
loading

Table of Contents