Gas fires with closed combustion system original bell-series - retro bell-series horizon bell medium / small-series - corner bell small l/r vertical bell-series - view bell-series (90 pages)
Page 1
INSTRUCTIONS FOR USE & INSTALLATION INSTRUCTIONS UNICA 200 L/R UNICA 300 Gas fi re with open combustion system Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re This document is an essential part of your gas fi re.
Bellfi res English CONTENTS Page 1. INSTRUCTIONS FOR USE ..............2. INSTALLATION INSTRUCTIONS ............3. MAINTENANCE ..................4. FAULTS ....................5. ELECTRICAL DIAGRAM ................ 6. DIMENSIONS ..................7. TECHNICAL DETAILS/REGULATIONS ..........8. REPLACEMENT PARTS LIST ..............Instructions for use & Installation instructions...
Page 4
Bellfi res English Instructions for use & Installation instructions...
Page 5
Bellfi res English Interfocos Warranty terms Interfocos B.V. guarantees the quality of the supplied Bellfi res hearth and the quality of the materials used. All Bellfi res hearths are developed and manufactured according to the highest possible quality standards. If, despite all this, something should prove amiss with the Bellfi...
Page 6
Bellfi res English it has not be used or maintained according to the instructions for use; it has been changed, neglected or roughly treated; it has been damaged as a result of external causes (outside the hearth itself), for example, lightning strike, water damage or fi re; 3.2.
Bellfi res English INSTRUCTIONS FOR USE INTRODUCTION Congratulations on your purchase of this modern BARBAS gas fi re. This quality product will provide you with many years of enjoyment due to the fl ame effect and warmth that it provides. Please read the instructions for use carefully before using the appliance for the fi...
Page 8
Bellfi res English 1.3 OPERATION GENERAL The gas regulating block, with which the fi re is operated, is located behind the operating hatch. The fi re has one main burner which can be operated by the thermostatic knob and/or the sliding knob. The thermostatic knob is used to choose the correct setting and the modulating thermostat ensures that the set temperature (13 - 38°C) is maintained.
Page 9
Bellfi res English 1.4 IGNITING THE FIRE • Open the gas supply valve in the gas pipe to the fi re. • Lock the slider into “l“ position. • Turn the thermostat knob to the ignition position “«“ and then push the knob in. •...
Page 10
Bellfi res English CONTROL OF THE APPLIANCE MODELS: UNICA 200 L - 400 / UNICA 200 R - 400 / UNICA 300 - 400 1.7.1 In general The pilot light and burner are switched to “ON “ or “OFF” by means of the control knob A.
Page 11
Bellfi res English Important : If the pilot light goes out, then wait for at least 5 minutes before repeating the above mentioned procedure. • Continue turning knob A fully to the left until the “ON” position, (the “big fl ame” symbol) and the main burner is ignited.
Page 12
Button TIMER Button Low MAN Setting TIMER Setting TIME Figure 4: Hand-held transmitter Unica 200 L - 400, Unica 200 R - 400 and Unica 300 - 400 Figure 5: 4 x Connectors to gascontrols Instructions for use & Installation instructions...
Page 13
Bellfi res English 1.7.5 Extinguishing the fi re Turn knob B, possibly with the remote control, fully to the right to the l -symbol and/or turn the control knob A to the right until the stop (“small fl ame” symbol = pilot light position).
Page 14
Bellfi res English 1.7.10 MAN mode for manual fl ame height adjustment • Press to turn on the fi re (main burner) or to increase fl ame height. • Press to decrease fl ame height or to turn down the main burner. The pilot stays on.
Page 15
Bellfi res English 1.7.15 Replacing the batteries The batteries of the hand-held transmitter and reciever have a lifespan of approximately one year. If BATT appears in upper right corner of the display, please change the battery from the hand-held transmitter. If the LED of the reciever becomes faint, please change the battery from the reciever.
Page 16
Bellfi res English 1.8 USING THE APPLIANCE FOR THE FIRST TIME The gas fi re is coated with a lacquer layer resistant to high temperature. During the fi rst hours of operation, the burning in of the lacquer may result in an unpleasant smell.
Bellfi res English INSTALLATION INSTRUCTIONS 2.1 GENERAL The gas fi re must be positioned and connected as a “open” appliance by a “Gas Safe Register” registered gas installation engineer in accordance with the following instal- lation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations”...
Page 18
Bellfi res English PREPARATIONS BEFORE INSTALLATION Before installing the appliance, fi rst observe the following instructions. 2.3.1 The most important facilities according to the regulations NATURALLY VENTILATED HOUSE (see Figure 6). • The room in which the appliance is to be fi tted must have a non- closable combustion air supply opening.
Page 19
Bellfi res English MECHANICALLY VENTILATED HOUSE (see Figure 7) • The room in which the appliance is to be fi tted must have a non- closable combustion air supply opening. The minimum dimensions are detailed in “Technical Details/Regulations” at the rear of this manual (see also Paragraph 2.4, point 2).
Page 20
Bellfi res English 2.4 GENERAL SERVICES 1. FLUE Before installation, it must be verifi ed that the fl ue has suffi cient draw. Remove all fl ue gas dampers (if present) in the fl ue or fi x them in the open position. The fl...
Page 21
Bellfi res English POSITIONING THE APPLIANCE Important : • Never use combustible materials during the installation. • Insulate the gas fi re using white loose insulation wool (heat resistant up to 1000°C). Not at the bottom !! • Flammable materials, such as curtains, should not be placed in the vicinity of the gas fi...
Page 22
Bellfi res English 2.5.2 Fitting into an existing opening larger than the fi re insert. Place an (insulated) aluminium or (fl exible) stainless steel pipe (Ø100 mm) into the fl ue for the connection between the fl ue spigot of the appliance and the chimney and then position the appliance into the fi...
Page 23
Bellfi res English Flue spigot Outer casing Inner shell / Combustion chamber Cover plate Front Door Control-unit Operating hatch Figure 8: Unica 200 L Flue spigot Outer casing Cover plate Inner shell / Combustion chamber Control-unit Front Door Side-cover Operating hatch Figure 9: Unica 200 R Instructions for use &...
Page 24
Bellfi res English Flue spigot Cover plate Outer casing Inner shell / Combustion chamber Control-unit Front Door Side-cover Operating hatch Figure 10: Unica 300 Installing the gas fi re insert should be carried out in the following order: FITTING THE OUTER CASING Place the outer casing into the fi...
Page 25
Bellfi res English FITTING THE INNER SHELL Before assembly, check that the sealing cords of the fl ue spigot and glass are still intact. Position the complete inner shell in the casing. Position the inner shell by, fi rst of all, fi tting loosely the 4 insert nuts, so that the inner shell is completely level against the front of the outer casing.
Page 26
However with the log set, only one bag (1x 125 gram) of embers may be placed on and around the burner. Vermiculite granules are not permitted and are therefore not supplied with appliances that use propane. Figure 11: Log set UNICA 200 L/R / UNICA 300 Instructions for use & Installation instructions...
Page 27
Bellfi res English FITTING THE FRONT, DOOR AND GLASS (WEAR PROTECTIVE GLOVES !!!) First of all, check that the sealing cord on the front side of the combustion chamber is still intact. After that, screw the front on the combustion chamber. After verifi...
Bellfi res English MAINTENANCE 3.1 ANNUAL MAINTENANCE The appliance must be checked and cleaned annually by an authorised engineer. This also applies to the chimney. The annual maintenance consists of the following points: • Cleaning the main burner, pilot light and fl ue exhaust. •...
Bellfi res English FAULTS Possible causes for the gas fi re going out are: • Operation of the security system due to fl ue gas escape. • Malfunction of the security system. Check by means of testing. • Insuffi cient gas pressure. •...
Bellfi res English ELECTRICAL DIAGRAM brown blue yellow / green brown brown Fanspeed controller convection-fan 230 VAC / 50 Hz Convection-fan 230 VAC / 50 Hz Thermostat “Clickson” set at ± 40°C Earthed plug (with earth sleeve) 230 VAC Cable clamp Connector Earth connector Instructions for use &...
Bellfi res English DIMENSIONS 6.1 UNICA 200 L Gas connection Gas connection * = Gas connection possibility bottom of the appliance !! Instructions for use & Installation instructions...
Page 32
Bellfi res English UNICA 200 R Gas connection connection * = Gas connection possibility bottom of the appliance !! Instructions for use & Installation instructions...
Page 33
Bellfi res English UNICA 300 Gas connection Gas- connection * = Gas connection possibility bottom of the appliance !! Instructions for use & Installation instructions...
Security system T.T.B. 140°C 319529 Glass Unica 300, Middle, 652 x 286 x 4 mm 319530 Glass Unica 200-300, L/R, 317 x 286 x 4 mm 319531 Glass Unica 200 L/R, 634 x 286 x 4 mm Instructions for use & Installation instructions...
Page 36
Bellfi res English Part no Description Standard (hand (remote control) control) 302155 Convection fan 230 VAC / 50 Hz. 302170 Fanspeed controller 230 VAC / 50 Hz. 302154 Clickson Black fi bre glass cord Ø10 mm; L= 1620 mm 301617 301595 Fibre glass tape 20 x 6 mm;...
Page 37
Bellfi res English Instructions for use & Installation instructions...
Page 38
Bellfi res English Instructions for use & Installation instructions...
Page 40
Your Bellfi res dealer 02 - 011014 - 331059...