1.7
CONTROL OF THE APPLIANCE MODELS:
UNICA 200 L - 400 / UNICA 200 R - 400 / UNICA 300 - 400
1.7.1
In general
The pilot light and burner are switched to "ON " or "OFF" by means of the control knob
A. The fl ame height of the burner is regulated by control knob B.
The desired position is selected and the burner will burn continuously in this position,
until this is changed.
The control knob B can be used in different ways:
1. Manually, by turning the knob by hand in the desired position.
2. By means of the cordless remote control, where the desired position of the knob and
also the fl ame height are regulated by ultra-sonic signals.
Figure 2: Operating switch model -400
1.7.2
Igniting the fi re
• Open the gas valve in the gas supply pipe to the appliance
• Turn the control knob B to the position where the "big fl ame"-symbol is located.
• Turn the control knob A a little to the left until the stop.
• Press knob A and keep the button pressed approximately 5 seconds (the gas fl ows
to the pilot light).
• Continue turning the pressed knob A further to the left to the ignition position (from
the « -symbol to the "small fl ame" symbol). A "click" is heard indicating the ignition
spark for the pilot light.
If necessary, click a few times until the pilot light burns.
• As soon as the pilot light burns, keep knob A pressed for another 10 seconds, then
release.