Download Print this page

Bellfires UNICA 200 L Instruction For Use & Installation Instructions page 25

Gas fire with open combustion system

Advertisement

Bellfi res
2
FITTING THE INNER SHELL
Before assembly, check that the sealing cords of the fl ue spigot and glass are still intact.
Position the complete inner shell in the casing.
Position the inner shell by, fi rst of all, fi tting loosely the 4 insert nuts, so that the inner
shell is completely level against the front of the outer casing.
Next, adjust the inner shell by means of adjustment bolts which are located on the
bottom left and right of the combustion chamber.
The fl ue spigot of the inner shell has to be tightly fi tted against the top side of the outer
casing.
Tighten all 4 insert nuts securely.
Place the back panel in the combustion chamber.
CHECK THAT THE SEALING CORD OF THE FLUE SPIGOT IS CORRECTLY
CONNECTED !
3
FITTING THE "CONTROL UNIT"
First of all, make the elctrical connection (when dismantled) on the connector on
the right-hand side. (Only applicable if the appliance is provided with a convection fan.)
While sliding the "control unit" underneath the inner shell, secure the (light blue) plug
connectors of the security system. For this purpose, the wires need to be led outside,
left along the inner shell, after which the plugs have to be pushed on the thermocouple
interrupter near the gas regulating block. The "control unit" must be pushed into the in-
ner shell as far as it will go. Fit the thermostat sensor by means of the clip to the bottom
plate.
Use 8 bolts to secure the "control unit" together with the cover plate (at the front in the
combustion chamber).
4
GAS AND ELECTRICAL CONNECTION
Use the supplied swivel to make the gas connection. Ensure that the gas regulating
block stays straight during the connection. Ensure that the gas regulating block and
pipework are not put under stress.
The mains electricity can now be restored to the wall socket.
(Only applicable if the appliance is provided with a convection fan.)
Check that all connections are completely gas tight using soapy water or a leak tester.
As a check, allow the fi re to burn briefl y (maximum 1 minute).
Following verifi cation that there are no leaks, fi nish off building in the fi re insert.
(See Chapter 1; Instructions for use.)