5. Press ''DEFROST'' (SELECT) switch, then repeat steps 2, 3, and 4 to program in next defrost time setting.
MAKE SURE A MINIMUM OF TWO HOURS IS MAINTAINED BETWEEN DEFROST TIME SETTINGS. IF
A TIME SETTING OF LESS THAN TWO HOURS IS PROGRAMMED INTO THE UNIT, A MOMENTARY
''ERROR'' MESSAGE WILL APPEAR ON THE MESSAGE DISPLAY WHEN OPERATOR TRIES TO EXIT
''DEFROST''. THE PROGRAM WILL NOT ALLOW THE OPERATOR TO EXIT THE DEFROST SETTING
UNTIL THE LESS THAN 2-HOUR DEFROST TIME IS CORRECTED. THE OPERATOR MUST PRESS
''CANCEL DEFROST'' (ADVANCE) SWITCH, THEN REPEAT STEPS 2, 3, and 4 TO PROGRAM COR-
RECTED DEFROST TIME INTO UNIT.
6. Repeat step 5 as many times as necessary to program desired number of defrost time settings into the Unit.
7. Press ''ERROR RESET'' switch two times to exit from MENU SELECTIONS.

PROGRAMMING ''SLEEP'' (SLEEP TIME) INTO UNIT

''SLEEP'' (SLEEP TIME) may be programmed into Unit to occur any time of the day after Unit automatic defrost
cycle has occurred. Unit will shut down (go into sleep time) and will not wake up (return to normal operation) until
programmed ''WAKE UP'' (WAKE UP TIME) has occurred. Program ''SLEEP'' (SLEEP TIME) into Unit as follows:
1. Refer to PROGRAMMING MENU SELECTIONS ONTO MESSAGE DISPLAY and bring up ''SLEEP'' on
message display. Press ''DEFROST'' (SELECT) switch to lock in on selection.
2. Press ''CANCEL DEFROST'' (ADVANCE) switch to bring up flashing hour number on display.
3. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance hours on display to desired hour. Press ''DE-
FROST'' (SELECT) switch to lock in hour on display.
4. After hour (time of day) has been locked in on message display, minute numbers will be flashing on display.
Press ''CANCEL DEFROST'' (ADVANCE) switch to advance minute numbers to desired minutes (time of
day). Press ''DEFROST'' (SELECT) switch to lock in minutes (time of day) on display.
5. Press ''ERROR RESET'' switch two times to exit from MENU SELECTIONS.

PROGRAMMING ''WAKE UP'' (WAKE UP TIME) INTO UNIT

''WAKE UP'' (WAKE UP TIME) may be programmed into Unit to occur any time of the day to wake Unit up (return
to normal operation) after ''sleep time'' has occurred. Program ''WAKE UP'' into Unit as follows:
1. Refer to PROGRAMMING MAIN MENU SELECTIONS ONTO MESSAGE DISPLAY and bring up ''WAKE
UP'' on message display. Press ''DEFROST'' (SELECT) switch to lock in on selection.
2. Press ''CANCEL DEFROST'' (ADVANCE) switch to bring up flashing hour number on display.
3. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance hours on display to desired hour. Press ''DE-
FROST'' (SELECT) switch to lock in hour on display.
4. After hour (time of day) has been locked in on message display, minute numbers will be flashing on display.
Press ''CANCEL DEFROST'' (ADVANCE) switch to advance minute numbers to desired minutes (time of
day). Press ''DEFROST'' (SELECT) switch to lock in minutes (time of day) on display.
5. Press ''ERROR RESET'' switch two times to exit from MENU SELECTIONS.