Locate the Unit so the following requirements are satisfied.
1. Locate close to a filtered plain water inlet supply line with a minimum water pressure of 12-psig.
NOTE: The FCB Dispenser refrigeration system is equipped with a condenser coil that is cooled by two
condenser coil fans. Circulating air, required to cool the refrigeration system's condenser coil, is drawn
in through the grilled panel on the right-hand side and is exhausted out through the opposite side
grilled panel. Restricting air circulation through the Unit will decrease its cooling efficiency.
2. When installing Unit in it's operating position, do not allow obstructions to block sides, top, and front of the
Unit which will block off cooling air intake to the inside of the Unit. Air flow through the Unit must be present
to provide adequate cooling for the refrigeration system.
Locate the Unit to provide the following clearances:
Top of unit
Open (24 inches min.)
Back side
0-inches
Sides
6 inches (min.)
Front
Open

INSTALLING UNIT

INSTALLING LEVELING LEGS

Very carefully, tilt Unit up and install LEVELING LEGS (item 13) on four corners of the Unit base.
INSTALLING DRIP TRAY SUPPORTS (ITEM
1. Install DRIP TRAY SUPPORT, LEFT (item 7) and DRIP TRAY SUPPORT, RIGHT (item 8) on front of the
Unit and secure with SCREWS (item 6) See Figure 7.
2. Place DRIP TRAY (item 9) on drip tray supports.
3. Place CUP REST (item 5) in drip tray.
INSTALLING DRIP TRAY DRAIN HOSE KIT (ITEM 10)
Install DRIP TRAY DRAIN HOSE KIT (item 10) on Unit as instructed in Installation Instructions provided with
the Kit.
PREPARING UNIT FOR CONNECTION TO SYRUP, CO
SOURCES
Route coiled up syrup, CO
INSTALLING PRIMARY CO
(see Figure 2)
WARNING: To avoid personal injury and/or property damage, always secure CO
upright position with a safety chain to prevent it from falling over. Should the valve become
accidentally damaged or broken off, CO
, and plain water lines out through hole provided in the Unit base.
2
REGULATOR ASSEMBLY ON CO
2
(ITEM 8)
7) AND
, AND CITY PLAIN WATER
2
cylinder can cause serious personal injury.
2
9
CYLINDER
2
cylinder in
2
2992

Advertisement

Table of Contents
loading

Table of Contents