Electrical Power Requirements; Two-Flavor Fcb Dispenser; Four-Flavor Fcb Dispenser; Selecting Location - Cornelius FCB POST-MIX DISPENSER Installation & Service Manual

Two or four-flavor w/hot-gas defrost and v3+features
Table of Contents

Advertisement

Item
No.
Part No.
10
326002
Kit, Drip Tray Drain Hose
11
2899
Wrench, Rear Seal Housing
12
3810
Tool, Drive/Coupler Adjustment Gauge
13
325018
Caster Kit, 4–inch diameter casters
∗ Νumbers in parentheses are in reference to items in Figure 4.
4. TAPERED GASKET, BLACK (item 4) is used to seal connection when connecting plain water source line to
Unit water inlet line.
5. DRIP TRAY SUPPORTS (item 7) to be installed on front of Unit and secured with THREAD CUTTING
SCREWS (item 6 ).
6. CUP REST (item 5 ) to be installed in DRIP TRAY (item 9 ), then drip tray to be installed in FRAME, DRIP
TRAY (item 8 ). Assembled drip tray assembly then to be installed on drip tray supports on front of the Unit.
7. WRENCH, REAR SEAL HOUSING (item 11) used to remove the drive shaft/seal assembly from inside the
freeze cylinder.
8. TOOL, DRIVE/COUPLER ADJUSTMENT GAUGE (item 12) is used for servicing the beater motor drive
shaft/seal assembly (see Figure 14).
9. DRIP TRAY DRAIN HOSE KIT (item 10) is to be installed on the drip tray as described in instructions
provided with the Kit.
10. CASTER KIT (item 13) to be installed on the Unit as instructed in Installation Instructions provided with the
kit.

ELECTRICAL POWER REQUIREMENTS

IMPORTANT: Before connecting electrical power to Unit, refer to nameplate and Note if Unit is to be
operated with 50 or 60 Hz power source.

TWO-FLAVOR FCB DISPENSER

A properly grounded 198-253 VAC, 60 Hz or 209-253 VAC, 50 Hz single-phase electrical circuit with a 30-amp
minimum-rated disconnect switch (not provided) fused at 30-amps (slow-blow) or circuit connected through an
equivalent HACR circuit breaker must be available to the Unit. ALL WIRING MUST CONFORM TO NATIONAL
AND LOCAL CODES. MAKE SURE UNIT IS PROPERLY GROUNDED.

FOUR-FLAVOR FCB DISPENSER

A properly grounded 198-253 VAC, 50Hz or 209-253 VAC, 50 Hz single-phase electrical circuit with a 50-amp
minimum-rated disconnect switch (not provided) fused at 50-amps (slow-blow) must be available to the Unit.

SELECTING LOCATION

IMPORTANT: Unit operating ambient temperature MUST NOT EXCEED 100° F. Operating ambient in
excess of 100° F will automatically void the factory warranty and will eventually result in Unit failure.
Several means are available to achieve proper ambient temperature and air circulation around the Unit
which are wall air intake grilles and ceiling exhaust fans, air conditioning, etc. Consult local codes.
Locate Unit so the following requirements are satisfied.