7. Press ''DEFROST'' (SELECT) switch. No. 1 defrost relay will click when switch is pressed.
8. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''DEFROST 2'' on message
display.
9. Press ''DEFROST'' (SELECT) switch. No. 2 defrost relay will click when switch is pressed.
10. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''SYRUP 1'' on message display.
11. Press ''DEFROST'' (SELECT) switch. No. 1 syrup solenoid relay will click when switch is pressed.
12. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''SYRUP 2'' on message display.
13. Press ''DEFROST'' (SELECT) switch. No. 2 syrup solenoid relay will click when switch is pressed.
14. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''WATER 1'' message display.
15. Press ''DEFROST'' (SELECT) switch. No. 1 carbonated water solenoid relay will click when switch is
pressed.
16. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''WATER 2'' on message display.
17. Press "DEFROST'' (SELECT) switch. No. 2 carbonated water solenoid relay will click when switch is
pressed.
18. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''RF SOL 1'' on message
display.
19. Press ''DEFROST'' (SELECT) switch. Refrigeration relay clicks when switch is pressed.
20. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''RF SOL 2'' on message
display.
21. Press ''DEFROST'' (SELECT) switch. No. 2 refrigeration solenoid clicks when switch is pressed.
22. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''COMPRESS'' on Message
display.
23. Press ''DEFROST'' (SELECT) switch. Compressor and condenser fan motor will start and operate while
switch is pressed.
24. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''HO PUMP'' on message
display.
25. Press ''DEFROST'' (SELECT) switch. Carbonator water pump relay on master circuit board clicks when
switch is pressed.
26. Press ''ERROR RESET'' switch two times to exit from MENU SELECTIONS.
DISPLAYING ''TOTALS'' (DISPLAYED CYCLES AND HOURS TOTALS) ONTO MESSAGE
DISPLAY
(see Table 4 and Table 8).
''TOTALS'' (DISPLAYED CYCLES AND HOURS TOTALS) may be displayed on message display as follows:
1. Refer to PROGRAMMING MAIN MENU SELECTION ONTO MESSAGE DISPLAY and bring up the word
''CLOCK'' on message display.
2. Repeatedly press and release ''CANCEL DEFROST'' (ADVANCE) switch to advance through main menu
until ''TOTALS'' menu appears on message display. Press ''DEFROST'' (SELECT) switch to lock
''TOTALS'' menu in place. The word ''COMP HRS'' will appear on message display.