Basic Tools Detail:
Table 2(Installer Setup):
Item
ID Code
Unlock Timing
Unlock Output
Card Manage
Doorplate Mode
Audio Options ...
Parameters ...
Installer Code ...
Default ...
-10 -
Description
If only one door station is installed in this building, set
to 0;
If multi door stations are installed, primary door station
must be set to 0, and other slave door stations must
be set from 1 to 3. Note that max. 4 door stations are
available in one building
To set the time that how long the door keeps open
when door is released. Range from 01 to 99 seconds.
To set the unlock mode to match the corresponding
lock.Range from 0 to 1.
0:Power-on-to-Unlock Mode(Normally Open Mode)
1:Power-off-to-Unlock Mode(Normally Closed Mode)
To set the card location.If set to 0,the card is saved in
door station.If set to 1, the card is saved in DT-IPC
To set the calling mode.If set to 0,it's the auto
mode,that means the calling will be activated directly
after inputting 2 digits code.If set to 1,it's the manual
mode,that means you should press "#" button to acti-
vate the calling after inputting the code.
To set talking mode,when cutting voice or mixed voice
appears,set to 1.
DS-IM talking:set the voice matching between Door
Station and Indoor Monitor
DS-NT talking:set the voice matching between Door
Station and Guard Unit
To show the parameters,please refer to table 2.1
To change door station administrator code
Note this operation is irreversible. Once restore is
activated, all parameters will return to factory default
setting except the information of access card.
Factory
set
[0]
Single
[05]
5 seconds
0
0
[0]
Auto mode
0
[66666666]