3. Operation

3.0. Master Keyswitch

To operate the system, turn the key switch located beside the strobe light, to the on
position. To override the system turn the key switch to the off position (you may
require this if you are unable to use the remote controls). Use one of the 2 high
security keys provided with the system.
OFF

3.1. Remote Control Functions

Press
Press
Press
ON
Button 1
AWAY mode
Press once to arm the system in normal AWAY mode.
The siren will beep once. The strobe will flash for 2 seconds.
STAY mode
Press twice within 3 seconds to arm in the system in STAY mode. The
siren will beep on each press. The second beep will be a low tone.
PANIC mode
Press and hold (approximately 3 seconds) to activate PANIC mode.
Button 2
DISARMING
Press once to disarm the system. The siren will beep twice. The strobe will
flash for 5 seconds.
LEARN NEW REMOTE mode
Press and hold (approximately 3 seconds) to activate learn new remote
mode.
Button 1 & 2
QUIET ARMING and DISARMING
For quiet AWAY arming or DISARMING press both buttons together,
once to arm the system in AWAY mode or to disarm the system without
any sound.
For quiet STAY arming press both buttons together, twice.
PROGRAMMING mode
Press and hold (approximately 3 seconds) to activate PROGRAMMING
mode after turning Safety Lock off. See section 4 (Programming).