Electrical Requirements - Manitowoc S Model Installation, Use & Care Manual

Ice beverage with cvd technology
Hide thumbs Also See for S Model:
Table of Contents

Advertisement

Section 2

Electrical Requirements

QuietQube® Ice Machine Head Section
Due to continuous improvements, this information is
for reference only. Please refer to the ice machine
serial number tag to verify electrical data. Serial tag
information overrides information listed on this page.
Local or state electrical code, length of wire run or materials used, can increase the minimum wire or breaker
size requirement. A qualified electrician must determine the wire and breaker size, although the minimum
wire size must meet or exceed the specifications in these charts.
Ice Machine
S0600C
S0850C
IB0620C
IB0820C
IB1020C
S1000C
S1200C
S1470C
S1870C
S2170C
* Not available on S2170C models.
** All conductors must be solid copper wire
Part Number 000002477 3/08
Important
Voltage
Maximum
Phase
Fuse/Circuit
Cycle
Breaker
115/1/60
15 amp
230/1/50
15 amp
115/1/60
15 amp
230/1/50
15 amp
115/1/60
15 amp
230/1/50
15 amp
115/1/60
15 amp
230/1/50
15 amp
115/1/60
15 amp
230/1/50
15 amp
115/1/60
15 amp
208-230/1/60
15 amp
230/1/50*
15 amp
**Minimum Wire Size
Total Amps
Required by Manitowoc
1.1
#14 Solid Copper
Conductor
0.6
1.1
#14 Solid Copper
Conductor
1.5
1.4
#14 Solid Copper
Conductor
0.8
2.5
#14 Solid Copper
Conductor
1.5
2.5
#14 Solid Copper
Conductor
1.5
1.1
#14 Solid Copper
0.6
Conductor
0.6
Installation Instructions
Minimum Breaker
Size Required by
Manitowoc
15 amp
15 amp
15 amp
15 amp
15 amp
15 amp
15 amp
15 amp
15 amp
15 amp
15 amp
15 amp
15 amp
2-13

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S Model and is the answer not in the manual?

This manual is also suitable for:

Quietqube

Table of Contents