Section 2
Ice Machine Head Section Installation
Requirements

S600C/S850C/S1000C/S1200C/S1470C/S1870C/S2170C

The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 35°F (1.6°C),
but must not exceed 110°F (43.4°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must not obstruct airflow through or
around the ice machine. Refer to ice machine head
section clearance requirements.

IB0600C/IB0800C/IB1000C

Ice/Beverage Ice Machines require the installation of
a thermostat to maintain dispenser ice level. The
thermostat ships with the ice machine.
The ice machine head is installed with the electrical
inlet, water supply inlet, refrigeration tubing and
water drain entering from the back of the ice
machine.
The ice machine head section contains a service
loop that must remain installed between the ice
machine head section and line set. Sufficient tubing
length must be available to allow 180° rotation of the
ice machine.
Maintain a 3" space between the back of the ice
machine and the back of the dispenser to allow room
for the refrigeration line set service loop.
The water inlet and electrical connection must
contain a service loop to allow future service and
maintenance access.
The drain line must contain a union or other suitable
means of disconnection at the ice machine head
section.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 35°F (1.6°C),
but must not exceed 110°F (43.4°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must not obstruct airflow through or
around the ice machine. Refer to ice machine head
section clearance requirements.
Part Number 000002477 3/08
Ice Machine Head Section Clearance
Requirements
S600C/S850C/S1000C/S1200C/S1470C/S1870C/S2170C
Top 5" (12.7 cm) is recommended for efficient operation
and removal of top cover/servicing.
Sides 5" (12.7 cm) is recommended for efficient
operation and servicing. There is no minimum clearance
required.
Back 3" (7.6 cm) required when routing electrical inlet,
water inlet and refrigeration tubing out of the top of the
unit.
5" (12.7 cm) required when routing all connections out
the back.
IB0600C/IB0800C/IB1000C
Top 2" (5.1 cm) required clearance for cleaning
procedures and servicing.
Back 5" (12.7 cm) required when routing all connections
out the back.
Sides 8" (20.3 cm) required for servicing.
The ice machine head section must be protected if it
will be subjected to temperatures below 32°F (0°C).
Failure
caused
by
temperatures is not covered by the warranty. See
"Removal from Service/Winterization".
Installation Instructions
! Caution
exposure
to
freezing
2-7