Quietqube® Ice Machine Head Section Electrical Wiring Connections; Quietqube® Ice Machine Head Section 115/1/60; For United Kingdom Only - Manitowoc S Model Installation, Use & Care Manual

Ice beverage with cvd technology
Hide thumbs Also See for S Model:
Table of Contents

Advertisement

Section 2
QuietQube® Ice Machine Head Section Electrical Wiring Connections
These diagrams are not intended to show proper
wire routing, wire sizing, disconnects, etc., only the
correct wire connections.
All electrical work, including wire routing and
grounding, must conform to local, state and national
electrical codes.
Though wire nuts are shown in the drawings, the ice
machine field wiring connections may use either
wire nuts or screw terminals.
QUIETQUBE® ICE MACHINE HEAD SECTION
115/1/60
L
1
GROUND
ICE MACHINE
CONNECTIONS

FOR UNITED KINGDOM ONLY

As the colors of the wires in the mains lead of the appliance may not correspond with the colored markings
identifying the terminals in your plug, proceed as follows:
The wire which is colored green and yellow must be connected to the terminal in the plug which is marked with
the letter E or by the earth ground symbol
The wire colored blue must be connected to the terminal which is marked with the letter N or colored black.
The wire colored brown must be connected to the terminal which is marked with the letter L or colored red.
Part Number 000002477 3/08
!
Warning
N=115V
OR
L2=208-230V
GROUND
QUIETQUBE® ICE MACHINE HEAD SECTION
230/1/50
GROUND
L
1
SV1258
or colored green or green and yellow.
Installation Instructions
L
1
N
ICE MACHINE
CONNECTIONS
L
1
N
GROUND
TO SEPARATE
FUSE/BREAKER.
DISCONNECT ALL
POLES.
SV1191
2-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quietqube

Table of Contents