17
Fetching data from external
Extech and FLIR meters

17.1 General

You can fetch data from an external Extech or FLIR meter and merge this data into the
result table in the infrared image.

17.2 Supported meters

Extech meters:
• Extech MO297
• Extech EX845
FLIR meters:
• FLIR CM78
• FLIR CM83
• FLIR DM93
• FLIR MR77

17.3 Technical support

• Extech meters: support@extech.com
• FLIR meters: http://support.flir.com

17.4 User documentation

• Extech meters: http://extech.com/instruments/
• FLIR meters: http://support.flir.com

17.5 Procedure

Note
This procedure assumes that you have paired the Bluetooth devices. For more information, see section
10 Pairing Bluetooth devices, page 19.
Follow this procedure:
1. Turn on the camera.
2. Turn on the FLIR meter.
3. On the meter, enable Bluetooth mode. Refer to the user documentation for the meter
for information on how to do this.
4. On the meter, choose the quantity that you want to use (voltage, current, resistance,
etc.). Refer to the user documentation for the meter for information on how to do this.
Results from the meter will now automatically be displayed in the result table in the
top left corner of the infrared camera screen.

17.6 Typical moisture measurement and documentation procedure

17.6.1 General
The following procedure can form the basis for other procedures using Extech or FLIR
meters and infrared cameras.
17.6.2 Procedure
Follow this procedure:
1. Use the infrared camera to identify any potential damp areas behind walls and
ceilings.
2. Use the moisture meter to measure the moisture levels at various suspect locations.
3. When a spot of particular interest is located, store the moisture reading in the mois-
ture meter's memory and identify the measurement spot with a handprint or other
thermal identifying marker.
4. Recall the reading from the meter memory. The moisture meter will now continuously
transmit this reading to the infrared camera.