Serial Communications - Avery Dennison Monarch 9485 System Administrator Manual

Portable printer
Hide thumbs Also See for Monarch 9485:
Table of Contents

Advertisement

4. The information label prints.
4. Following message appears according to the result.
5. Press any key to exit from the Menu.
**Setting the Detect
This Menu can activate or deactivate Width-Detect Function.
1. Select Toolbox – Setup – Printer – Detect.
If "Enable" is selected and the supply less than 1 inch-width is detected, printing speed is reduced.
(Default : Disable)
DETECT SENSOR
34

3-1-5. Serial Communications

You can set serial communication using this Menu.
The following values must be set for serial communication with PC.
Option
Choices
1200/2400/4800/9600/
Baud Rate
19200/38400/57600/115200
Parity
None/Odd/Even
Data Bits
7/8
Stop Bits
1/2
No Flow/DTR Flow/
Flow Control
RTS Flow/Xon/Xoff/Special
Defualt
9600
None
8
1
DTR
35