Features; Overview - Bosch Solution 144 Quick Start Manual

Hide thumbs Also See for Solution 144:
Table of Contents

Advertisement

Solution 144
Quick Start Guide
Fe at ure s
Listed below are the main features of the Solution 144
Control Panel.
Individual Box Tamper Circuit Monitoring
Report Via Email (Internet)
Telephone Line Busy Tone Detect
RAS Intelli-Connect® CLI Caller Line Identification
Daylight Savings
Senior Watch
GSM/GPRS/Ethernet Reporting Options
System Maintenance Interval Reminder
System Weekly Test Reminder
Area Inactivity Interval
Up to 16 Access Doors
Temporary PIN
Dual Reporting
Dual Redundant Reporting
Alarm Report Abort/Cancel Options
8 Programmable Holiday Calendars
16 Programmable TimeZones
8 On-board Zones (Single EOL) / 16 On-Board Zones
(Dual EOL)
Expandable To 144 Zones)
Fire Alarm Verification
255 PIN Users
4 Supervised High Power Digital Outputs
1 Relay 2 Amp Form (C) Contact (Expandable to 32)
Supervised Siren Driver
Partitionable To 8 Areas
Dialler Reports SIA, Contact ID, SMS and Email
Formats
Supervised LAN Keypads (Maximum 16 Keypads)
Keyswitch Input
1000 History Event Memory
EMI / Lightning Transient Protection
Fully Menu Text Programmable
Programmable Via Solution Link Software (Remote/
Direct)
Telephone Line Fail Monitor
TimeZone Executed Functions
60+ Output Event Types
Exit Restart
Expansion Module Supervision
DTMF Tone Decoder Built In
Remote Arming
Fingetprint Reader Options
4
O ve r vi ew
Zones
The Solution 144 control panel provides up to 144 separate
zones of protection. Zone programming determines the
panel's response to open/short and tamper conditions on
the zone loop.
Areas
The control panel supports up to 8 separate areas. You can
assign all zones to a single area, or you can assign each
zone to a combination of different areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Dialler
The control panel has a built-in dialler to send reports
to the receiving party (ie. Security company monitoring
station, mobile phone etc).
Keypads
You can connect a maximum of 16 fully supervised keypads
to the control panel. The available current affects the total
number of keypads that you can connect without the need
to provide additional power supplies.
History Log
The control panel can store up to 1000 history events from
all 8 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel's history log via keypad,
or by connection of a personal computer (direct/remote)
using the SolutionLink upload/download software.
Programming
You can program the Solution 144 either by a keypad or
using a personal computer using the Solution Link upload/
download software.
Bosch Security Systems 10/12 BLCC600R

Advertisement

Table of Contents
loading

Table of Contents