Input Programming - Bosch Solution 144 Quick Start Manual

Hide thumbs Also See for Solution 144:
Table of Contents

Advertisement

Solution 144
Quick Start Guide
Areas > Timers >
Auto Arm Pre Alert
(*** System Wide Parameter ***)
Enter 000 – 255 + [OK] to program the pre-alert time in
minutes (0 = No Pre-Alert).
Areas > Timers >
Senior Watch Time
(*** System Wide Parameter ***)
Enter 000 – 255 + [OK] to program the senior watch
interval in hours.
Areas > Area Testing >
Area Watch
(*** System Wide Parameter ***)
Enter 000 – 255 + [OK] to program the number of weeks
before registering an inactivity event.
Areas > Area Testing >
User Test Interval
(*** System Wide Parameter ***)
Enter 000 – 255 + [OK] to program the number of days
before a user test is requested.
Areas > Area Testing >
Service Interval
(*** System Wide Parameter ***)
Enter 000 – 255 + [OK] to program the number of weeks
required between installer services.
Areas > Area Testing >
Test Options
1 User Test Required
2 Reserved
3 Reserved
4 Reserved
5 Reserved
6 Walk Test Report
7 Walk Test 24Hr
8 Walk Test Fire
Use the [] and [] keys to scroll the list of options. Select
the option required, then press [ON] or [OFF] to enable or
disable. A [] will display to indicate option set. Press [OK]
to save when finished.
30
I np ut Programming
MENU 2-8-4
Inputs > Commands >
0 0 0
Zone Status
Minutes
Zone Array
Bypass Zones
Set Chime Zones
MENU 2-8-6
Set Part 2 Zones
0 0 0
Smoke Sensor Reset
Hours
Inputs > Zone Properties >
Zone Name
Z o n e
MENU 2-9-0
Use the [] and [] keys to scroll cursor left and right.
0 1 2
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
Weeks
text from the current cursor position.
Inputs > Zone Properties >
MENU 2-9-1
Zone Type
0 0 0
Days
00 - Not Used
01 - Burglary Delay 1
02 - Burglary Delay 2
03 - Burglary Instant
04 - Burg Inst No Exit
MENU 2-9-2
05 - Burg Handover
0 0 0
06 - Burglary 24Hr
07 - Tamper 24Hr
Weeks
Use [] and [] keys or enter 0 – 15 + [OK] to program the
zone type.
Inputs > Zone Properties >
MENU 2-9-3
Area Assignment
Y
N
N
00 - No Area
N
01 - Security System
N
02 - Area 2 Name
Y
03 - Area 3 Name
N
04 - Area 4 Name
N
Use [] and [] keys or enter 0 - 8 then press [OK] to
program.
1
N a m e
08 - Hold Up 24Hr
09 - Medical 24Hr
10 - Panic 24Hr
11 - Fire 24Hr
12 - Not Used
13 - Keyswitch Zone
14 - Display Only
15 - Non Burglary 24Hr
05 - Area 5 Name
06 - Area 6 Name
07 - Area 7 Name
08 - Area 8 Name
Bosch Security Systems 10/12 BLCC600R
MENU 3-0-0
MENU 3-0-1
MENU 3-0-2
MENU 3-0-3
MENU 3-0-4
MENU 3-0-5
MENU 3-1-0
MENU 3-1-1
0 1
MENU 3-1-2
0 1

Advertisement

Table of Contents
loading

Table of Contents