Addon Timer

Product Reference Guide
When addons have been selected as optional, this feature sets the duration
of time that the scanner can unsuccessfully look for an addon before pro-
ceeding to read a bar code. Timer duration is specified in 10ms incre-
ments.
To set the Addon Timer:
1. Scan the SWITCH bar code.
2. Scan the bar code,
need to cover any unused bar codes on this and the facing page to
ensure that the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the keypad in
resent the desired Addon Timer Duration. The selectable range is 1-
10, which is the timeout in 10-millisecond increments. Pad all sin-
gle and double digit numbers with leading zeroes to yield a three-
digit entry (001-010).
Examples:
001 = 10ms
003 = 30ms
008 = 80ms
Complete the programming sequence by scanning the SWITCH bar
code.
SET ADDON TIMER DURATION
SET ADDON TIMER DURATION