Pilot & Thermocouple Maintenance - ORTAL Clear 40 Tunnel, Clear RS Tunnel Installation & Operation Manual

40 series; 70 series; 80 series; 110 series; 120 series; 130 series; 135 series; 150 series; 170 series; 200 series;
Hide thumbs Also See for Clear 40 Tunnel, Clear RS Tunnel:
Table of Contents

Advertisement

Pilot Maintenance
The pilot flame must be visually checked. Always be present when the fireplace is in operation.
.
The pilot flame has two distinct flames, one engulfing the thermocouple, and the other reaching
the main burner. Both flames must be present.
The area around the injector should be inspected, and any lint or foreign material must be
removed with a brush or vacuum.
Thermocouple Maintenance
The thermocouple completeness and operation must be checked.
Installer must confirm that the thermocouple is in place and not cracked or damaged.