Technical Specifications - ORTAL Clear 40 Tunnel, Clear RS Tunnel Installation & Operation Manual

40 series; 70 series; 80 series; 110 series; 120 series; 130 series; 135 series; 150 series; 170 series; 200 series;
Hide thumbs Also See for Clear 40 Tunnel, Clear RS Tunnel:
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATIONS

Gas combination control according to CSA or CE
FUELS
CSA: S uitable for natural, manufactured, mixed gases,
tures.
CE: Suitable for use with gases of EN 437 gas family
1, 2 and 3.
APPROVALS
CSA: ANSI Z21.78/CSA 6.20 for U.S. & Canada
CSA: ANSI Z21.20/CSA 6.20 for U.S. & Canada
CE: Gas Appliances Directive 90/396/EEC and EN
298-2003, DIN EN 126
Infrared Handset: GADAC Guidance Sheet B12
PRESSURE DROP/CAPACITY
CSA: 1" W.C. at 65,000 BTU/hr
CE: 2,5 mbar at 1,2 m³/h air
RANGE OF REGULATION
CSA: 10,000 to 85,000 BTU/hr
CE: Class C according EN 88
REGULATOR ADJUSTMENT
CSA: 3" W.C. to 5" W.C. (7.5 to 12.5 mbar); 8" W.C. to
12" W.C. (20 to 30 mbar)
CE: 5 to 40 mbar
CE+CSA: 3" W.C. to 12" W.C. (7.5 to 30 mbar)
Convertible Regulator: 3 to 4.5" NG/8.5 to 11.5" LP
MOUNTING POSITION
Mount valve 0° to 90°, in any direction (including
vertically) from the upright position of the gas control
knob.
MAXIMUM INLET PRESSURE
CSA: ½ psi (34.5 mbar)
CE: 50 mbar (20" W.C.)
MAIN GAS CONNECTION
CSA: ⅜ in. NPT; Rp ⅜ ISO 7-1 internal thread for 12 mm,
10 mm, 8 mm, 6 mm outside diameter tube.
CE: Rp ⅜ ISO 7-1 internal thread for 12 mm, 10 mm,
8 mm, 6 mm outside diameter tube.
INLET AND OUTLET CONNECTION
Side or Bottom
MAXIMUM ALLOWED TORQUE INLET AND OUTLET
CSA: 280 inch-pounds
CE: 35 Nm
PILOT GAS CONNECTION
CSA: 7/16-24 UNS for 1/4" or 3/16" tubing
CE: M10x1 for 4 mm or 6 mm tubing
APPENDIX B
THERMOCOUPLE/INTERRUPTER BLOCK
11/32-32 UNF, M10x1, M9x1, M8x1
AMBIENT TEMPERATURE RANGE
Combination control: 32 °F to 176 °F (0 °C to 80 °C)
Latching solenoid valve: 32 °F to 176 °F (0 °C to 80 °C)
Receiver RF without batteries: 176 °F (80 °C)
-
Receiver RF with batteries: 140 °F (60 °C)
Receiver infrared with/without batteries: 140 °F (60 °C)
Handset: 140 °F (60 °C)
Wall switch/touch pad: 176 °F (80 °C)
Switch panel: 221 °F (105 °C)
Module: 176 °F (80 °C)
Ignition cable: 302 °F (150 °C)
Misc. cables: 221 °F (105 °C)
Infrared sensor: 176 °F (80 °C)
Cable with relay: 158 °F (70 °C)
HANDSETS
NOTICE
The handsets, receivers, wall switches, switch panels
and touch pads are not interchangeable with previ-
RADIO FREQUENCY
433.92 MHz for Europe
315 MHz for U.S. (FCC ID: RTD-G6R) and for Canada
(IC: 4943A-G6R).
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired opera-
by the party responsible for compliance could void the
user's authority to operate the equipment.
BATTERIES – HANDSET
1 x 9V (quality alkaline recommended)
BATTERIES – RECEIVER
4 x 1.5V "AA" (quality alkaline recommended)
An AC Mains Adapter may be used instead of batteries.
NOTICE
Only the Mertik Maxitrol AC Mains Adapter or one
preapproved by Mertik Maxitrol can be used. Use
of other adaptors can render the system inoperable.
V MODULE
CE: Inlet: 230VAC/50 Hz; 210 VA
Outlet: 230VAC/50 Hz; 100VA
Built-in fuse 2,5A
CSA: Inlet: 115VAC/60 Hz; 210 VA
Outlet: 115VAC/60 Hz; 100VA
Built-in fuse 2.5A
4 / 65
FOR OEM USE ONLY
Figure 8: Previous Handset