APPENDIX E

Thermocouple

Thermocouple check list Refer to figure 7A
1) Place new batteries are in the receiver.
2) Check for any breakage to the thermocouple from pilot assembly to the valve.
3) Confirm the thermocouple is tight to the interrupter block and the thermo current
cable is securely touching the end of the thermocouple.
4) Confirm the interrupter block is screwed in to the valve properly and finger tight.
5) Confirm thermo current cable TC is screwed in to the receiver properly and tight.
6) Confirm thermo current cable SW is screwed in to the receiver properly and tight.
7) Confirm the thermo current cable SW is securely place in the interrupter block.
7 |