Alarm Setup - Security Labs 960H Series User Manual

Table of Contents

Advertisement

【Alarm Input】Similar to other setup menus, select a channel to modify (or All).
【Input Type】All alarm trigger switches or devices are categorized as:
Normally Open (NO) = A switch, sensor, or other circuit that triggers an alarm when it is closed
(contacts touching).
Normally Closed (NC) = A switch, sensor, or other circuit that triggers an alarm when it is
opened (contact separated or wire broken).
Set each channel for the type of device that is connected to the alarm input terminal on the
back of the DVR. If no device is connected to a channel, leave the input type for that channel
as Normally Open (NO).
【Clear Alarm】Use the drop list to select a time period for the duration of an alarm recording.
【PTZ Relate】If you have a compatible PTZ camera model, when an alarm is triggered a
selected point or tour can be initiated. Click on <Setup> to make your selection from the
preset positions or tours that you previously created under PTZ Control in the shortcut menu
list.
【Trigger Recording】Select any combination of channels you wish to record when the alarm
is triggered for the channel you are working with.
【Alarm Output】Click to light up the button and make the alarm output relay active for this
channel.
41

Advertisement

Table of Contents
loading

Table of Contents