Refi t and Check Window
1. To facilitate the installation of the window, hook the
side spring-loaded levers to the side shrouds as
indicated so they are not in the way of the window
frame.
2. Place the window in its bottom railing and rotate its
top against the fi rebox.
Bottom railing
34
Installation
Window
frame
3. While you hold it, unhook the side levers from
the side shrouds and hook them into the window
brackets on each side.
4. Pull out the top of the window and release it to
ensure the springs return it.
IMPORTANT: To ensure a safe operation,
verify that the levers are hooked properly to the
window tabs; then, pull out the top of the window
and release it to insure the springs return it.
5. Apply light hand pressure against the window frame
sides to bed-in the window seal.
6. If the hot glass safety plate has been removed
from the front of the window, put it back in place
as indicated.
Safety warning plate