Clearances - Valor Legend G3.5 700IN Owner's Manual

Direct vent gas insert
Hide thumbs Also See for Legend G3.5 700IN:
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Some materials or items, although safe, may discolor, shrink, warp, crack, peel,
and so on because of the heat produced by the fi replace. Avoid placing candles,
paintings, photos, and other items sensitive to heat around the fi replace.
With optional
Fan: depth
+3" (76 mm)
WARNING
!
HOT GLASS! The use of a screen in front of the
glass is highly recommended particularly in
households with children.
sidewall
4" (102 mm)
20

Clearances

WARNING
!
A
Do not put
furniture or
objects within
B
36" (914 mm)
of the front of
appliance
Non-combustible hearth
Combustible Mantel Clearances
Mantel Pro-
0-6"
jection A
(0-152 mm)
Mantel
33"
Height B*
(838 mm)
*Measure taken from the underside of the mantel to fi nished
hearth or surface that the unit is sitting on.
Finishing Materials
Combustible materials: Material such as wood,
compressed paper, plant fi bers, plastics or any material
capable of igniting and burning, whether fl ame-proofed
or not, plastered or un-plastered.
Non-combustible materials: Material such as steel,
iron brick, tile, concrete or materials that bear the UL
mark for zero (0) fi re rating.
WARNING
!
HOT HEARTH / FLOOR! The hearth or fl oor in
front of the fi replace may become very hot
when the fi replace heats. Do not use the hearth
as a seat or shelf. Solid wood fl ooring in front
of the fi replace (if allowed) may shrink during
the heating season due to heat.
Sidewall Clearances
Minimum distance from side of appliance (liner box) to
combustible wall: 4" (102 mm).
8"
10"
12"
(203 mm)
(254 mm)
(305 mm)
35"
37"
39"
(890 mm)
(940 mm)
(990 mm)