Testing The System - Bosch Solution 16plus Quick Start Manual

Hide thumbs Also See for Solution 16plus:
Table of Contents

Advertisement

Solution 16
Quick Start Guide
plus
System > System Options >
General Options
1
Display LAN Fail
2
Report LAN Fail
3
Alarm On LAN Fail
4
Reserved
5
Can Change Own PIN Code
6
Monitor Default PIN Codes
7
PIN Always Required
8
Display Menu Numbers
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
(*** System Wide Parameter ***)
System > System Options >
Area Options
1
Area 1 = Common Area
2
First To Open Last To Close
3
Reset Siren All Users (All Areas)
4
Power Up In Same State As Powered Down
5
Fault Acknowledge All Areas
6
Delay Trouble Beeps
7
Power Up Disarmed
8
Reserved
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
(*** System Wide Parameter ***)
System > Options >
Keypad Idle Screen
0 = No Idle Screen
1 = Date and Time
2 = Time
3 = Custom Screen
Use Keys [] and [] keys or enter 0 - 3 Then Press [OK] To Program
The Keypad Idle Screen - Single Option Only.
System > Options >
Keypad Hi/Lo Temp
(*** System Wide Parameter ***)
Use Keys [] and [] keys To Program The High / Low Keypad Monitor
Temperature. Max = 50 Min = 0
32
MENU 7-7-0
MENU 7-7-1
MENU 7-7-2
(*** System Wide Parameter ***)
MENU 7-7-3
0
0
˚C
0
0
Hi TEMP
Lo TEMP
System > Installer Options >
Installer Options
1
Report/Log Entry/Exit Intstaller Menu
Y
2
Report/Log Program Data Change
Y
3
Arm Only Installer Pin
N
4
Reserved
N
5
Auto Exit Installer Menu In 2 Hours
N
6
Auto Exit Service mode In 2 Hours
Y
7
Reserved
N
8
Factory Defaulting Allowed
Y
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
(*** System Wide Parameter ***)
System >Options >
Language
0 = English
N
1 = Alternate Language
N
(Enter Digits 0 – 15 To Program Area, Output or Access Group Number,
Y
Then Press [OK] To Save
Y
System > System Testing >
Y
Walk Test All Zones
Y
N
Battery Test
N
Tes ting The System
You will need to be in programming mode before accessing
the test functions listed below.
Walk Test
Use the walk test command MENU 3-9-0 to test and verify
0
that all zones work correctly.
External Audible Test
Use MENU 4-9-0 to test and verify that all horn speakers
operate. This test will sound the horn speaker for two
seconds.
Internal Audible Test
Use MENU 4-9-1 to test and verify that all 12 VDC sirens
operate. This test will sound the siren for two seconds.
Strobe Test
˚C
Use MENU 4-9-2 To test and verify that the strobe operates.
This test will turn on the strobe until you manually stop the
test.
Battery Test
Use MENU 7-9-1 to test the back-up battery that is
connected to the control panel.
MENU 7-7-4
N
Y
N
N
Y
Y
N
Y
MENU 7-7-5
0
MENU 7-9-0
MENU 7-9-1
Bosch Security Systems 09/06 BLCC100R