Ab o u t Th e Pan el
M o u ntin g Th e Cabi n et
The cabinet should be mounted via 4 (screws/bolts)
through the 4 mounting holes in the base. Ensure that
the enclosure is mounted on a solid, flat, vertical surface
such that the base will not flex when tightened. Cabinet
dimensions are shown below.
375

Figure 1 : Cabinet Dimensions

M o du le S paces
Each cabinet has 4 identical module spaces and 1 large
module space that is allocated for non Solution PCB boards
(eg. a securitel STU).
Each space includes 4 x 10mm stand-offs that the optional
expander PCB boards will mount using screws (screws will
be supplied with each board). The expander board will be
earthed via the screws that mount the PCB to the metal
box.
All modules will mount on these module spaces.
A list of the PCB boards is detailed below
Module
Solution 16
Control Panel
plus
CM104 Zone Expander
CM110 Output Expander
CM120 LAN Power Supply
CM195 RF Receiver Expander
Using the above table, the installer can determine how
many modules can be mounted in a single cabinet box. On
some export models, module 3 will not be available as the
transformer mounts in this location.
Bosch Security Systems 09/06 BLCC100R
90
Space Occupied

2 Module Spaces

1 Module Space
1 Module Space
1 Module Space
1 Module Space
Figure 2: Metal Box – Module Space Allocations
Pa ne l Led I nd ic ators
The Solution 16
plus
PCB has two LED indicators (Dialler and
Status LED's) which display the following information.
Condition
Off
On
Flashing

Table 1: Dialler LED Meanings

Condition
Off
On
Flash Once Every 2 Seconds
Flash Fast

Table 2: Status LED Meanings

During factory defaulting the Status and Dialler
i
LED indicators will be on steady for approximately
Note
15 seconds.
Pa nel Ad d ress S ele c t
The Solution 16
plus
pcb has three DIP switches (called Panel
Node Select) that must be set. In a multi-panel system, each
control panel (Node) must to be set to a unique address.
Panel NODE Select DIP Switch Address Settings
Panel to Address
Panel 1
Panel 2
Panel 3
Panel 4
Panel 5
Panel 6
Panel 7
Panel 8

Table 3: Panel Node Select

The node switch should be left at Panel 1 position
i
for Solution 16
plus
Note
this switch may have been omitted. This is not a
fault.
Solution 16
Quick Start Guide
plus
Meaning
Offline
On Line (Dialling/Answered)
Incoming Call
Meaning
Error
Error
OK
AC or Battery Trouble
S1
S2
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
. OFF-OFF-OFF. On later versions
S3
Off
Off
Off
Off
On
On
On
On
5