Featu re s
Listed below are the main features of the Solution 16
Control Panel.
 Individual Box Tamper Circuit Monitoring
 Report Via Email (Internet)
 Telephone Line Busy Tone Detect
 RAS Intelli-connect® CLI Caller Line Identification
 Daylight Savings
 Senior Watch
 System Maintenance Interval Reminder
 System Weekly Test Reminder
 Area Inactivity Interval
 Temporary Pin Code
 Dual Reporting
 Dual Redundant Reporting
 Alarm Report Abort/cancel Options
 8 Programmable Holiday Calendars
 8 Programmable Schedules
16 fully programmable Zones
 Fire Alarm Verification
 48 Pin Codes
 3 Supervised High Power Digital Outputs
 1 Relay 2 Amp Form (C) Contact (Expandable to 13)
 Supervised Siren Driver
 Partitionable To 8 Areas
 Dialler Reports SIA, Contact ID, SMS and Email Formats
 Supervised LAN Keypads (Maximum 8 Keypads)
 Keyswitch Input
 256 History Event Memory
 EMI / Lightning Transient Protection
 Fully Menu Text Programmable
 Programmable Via Solution Link Software
(Remote/Direct)
 Telephone Line Fail Monitor
 Time Executed Functions
 60 Output Event Types
 Exit Restart
 Expansion Module Supervision
 DTMF Tone Decoder Built In
 Remote Arming
4
O ve r v iew
plus
Zones
The Solution 16
plus
zones of protection. Zone programming determines the
panel's response to open/short and tamper conditions on
the zone loop.
Areas
The control panel supports up to 4 separate areas. You can
assign all zones to a single area, or you can assign each
zone to a combination of different areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Dialler
The control panel has a built-in dialler to send reports to the
receiving party (ie. Security company monitoring station,
mobile phone etc).
Keypads
You can connect a maximum of 8 fully supervised keypads
to the control panel. The available current affects the total
number of keypads that you can connect without the need
to provide additional power supplies.
History Log
The control panel can store up to 256 history events from
all 8 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel's history log via keypad,
serial printer (optional), or by connection of a personal
computer (direct/remote) using the SolutionLink upload/
download software.
Programming
You can program the Solution 16
using a personal computer using the Solution Link upload/
download software.
control panel provides up to 16 separate
plus
either by a keypad or
Bosch Security Systems 09/06 BLCC100R