Tip: Use the option Edge to measure TFT/OFET fabricated with Ossila masks or with equivalent
masks, i.e. with single-layer dielectric substrates whose gate pads are located on the bottom left and
right corners. Use Match or UserM to characterise transistor architecture defined by separate gate
dielectric layers, one for each device column.
In order to minimise the gate leakage current, it is of paramount importance to keep the number of
active gates to a minimum (possibly no more than two) at any given time during the measurement.
Log data
User Name is used to enter the name of the person in charge of the experiment
Experiment Name is the experiment identification name. In continuous measurement mode, the
appositely created Experiment Name directory will contain all the experiments sharing the same
identification name.
Substrate Type is the substrates identification name. In continuous measurement mode, the
appositely created Substrate Type directory will contain all the experiments sharing the same
experiment and substrate identification name.
Folder is the existing directory in which the data files of a finite mode acquisition are saved.
Tip: To avoid imputing the wrong directory path, use the browse button to navigate to the selected
folder.
In continuous mode, this entry is locked and showing the data storage volume.
File Name is the (base) name for the data logging file.
Folder Button, if enabled, forces the data files to be saved in an appositely created directory
(command not available in continuous measurement mode).
Tip: It is recommended enabling this option to neatly save the data files in a single folder per
substrate. If you wish to add files to an existing substrate folder, disable this option and use
the Folder command to select the existing substrate directory.
Time Stamp forces a time stamp to be added in front of the file and folder name (command
not available in continuous measurement mode).
Tip: Enabling time stamp helps better keep track of past experiments while avoiding name
conflict when using the Start button to run repeated acquisition of the same substrate.
Data logging tree
Important: SuperFACT requires MS Excel 2007, or later version, to be installed on the host computer
in order for the application to execute properly.