Malfunctions Of The Appliance; The Appliance Does Not Work; The Appliance Operates But The Water Temperature Does Not Rise; The Fan Turns But The Compressor Stops From Time To Time Without An Error Message Appearing - Zodiac PF 11M Installation Instructions Manual

Heat pump for swimming pool
Hide thumbs Also See for PF 11M:
Table of Contents

Advertisement

2.2 Malfunctions of the appliance

2.2.1 The appliance does not work

Causes
No display
The pool temperature is above the temperature
setpoint.
A message is on the screen.

2.2.2 The appliance operates but the water temperature does not rise

Causes
Not enough filtering time
Non-complying period of use
The heat pump is under-dimensioned.
The automatic pool water filler is jammed in open
position.
The heat insulating cover is not used.
The evaporator is fouled.
The appliance is badly installed.
2.2.3 The fan turns but the compressor stops from time to time without an error
message appearing
Causes
The heat pump does defrosting cycles from time to
time.
The evaporator is fouled.

2.2.4 The heat pump trips out or attempts to start itself from time to time

Causes
The circuit breaker is under dimensioned or badly
dimensioned.
The cable section is to small.
The supply voltage is to low.
Verification / solution
Check the supply voltage and the fuse
Increase the temperature setpoint.
Check the meaning of message §2.1
Verification / solution
Put the filtering on manual 24/24 hours to raise
the temperature.
Check whether the heat pump is of the right
dimension for this period of the year.
Check the characteristics of the heat pump
according to the pool.
Checking correct operation of the automatic filler.
Put on the heat insulating cover.
Clean the evaporator (see §3.1)
The appliance must be installed outdoors.
Make sure there is no obstacle less than 4
metres from where the blower is facing, and 0.50
metre behind the heat pump.
Verification / solution
Normal if the outside temperature is lower than
12 °C.
Clean the evaporator.
Verification / solution
Check the circuit breaker (see § 1.4.5.1).
Check the cable section (see §1.4.5.3)
Call your electricity board.
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf15m

Table of Contents