4. Power on Utilities

There are six power-on utilities to set up and test printer hardware. These utilities are activated
by pressing FEED button and by turning on the printer power simultaneously.
The utilities are listed as below:
1.

Gap/Black Mark sensor calibration

2.
Gap/black mark sensor calibration, Self-test and Dump mode
3.
Printer initialization
4.
Black mark sensor calibration
5.
Gap sensor calibration
6.
Skip AUTO.BAS
4.1 Gap/Black Mark Sensor Calibration
Gap/black mark sensor sensitivity should be calibrated at the following conditions:
1. A brand new printer
2. Change label stock.
3. Printer initialization.
Please follow the steps below to calibrate the gap/black sensor:
1.Turn off the power switch.
2. Press and hold the Feed button while turning the power back on.
3 Release the button when LED becomes red and blinking. (Any red will do during the 5
blinks).
It will calibrate the gap/black mark sensor sensitivity.
The LED color will be changed as following order:
Amber
red (5 blinks)
blinks)
red/amber (5 blinks)
It calibrates the sensor and measures the label length.
Note:
Please select gap or black mark sensor using the GAP or BLINE command prior to
calibrating the sensor.
For more information about GAP and BLINE command, please refer to WPL
programming manual.
amber (5 blinks)
green (5 blinks)
solid green
11