Suzuki GSF650S Service Manual page 63

Hide thumbs Also See for GSF650S:
Table of Contents

Advertisement

Tighten the camshaft journal holder bolts evenly and diagonally
to the specified torque.
# Camshaft journal holder bolt: 10 N·m (1.0 kgf-m)
NOTE:
Do not rotate the camshafts with the plastigauge in place.
Remove the camshaft journal holders and measure the width of
the compressed plastigauge using the envelope scale. This
measurement should be taken at the widest part of the com-
pressed plastigauge.
If the camshaft journal oil clearance exceeds the limit, measure
the inside diameter of the camshaft journal holder and the out-
side diameter of the camshaft journal. Replace the camshaft or
the cylinder head depending upon which one exceeds the spec-
ification.
) 09900-20602: Dial gauge (1/1 000 mm)
09900-22403: Small bore gauge (18 – 35 mm)
( Camshaft journal holder I.D. (IN & EX)
Standard: 22.012 – 22.025 mm
) 09900-20205: Micrometer (0 – 25 mm)
( Camshaft journal O.D. (IN & EX)
Standard: 21.959 – 21.980 mm
CAMSHAFT RUNOUT
Measure the runout using the dial gauge. Replace the camshaft
if the runout exceeds the limit.
) 09900-20606: Dial gauge (1/100 mm)
09900-20701: Magnetic stand
09900-21304: V-block set (100 mm)
( Camshaft runout (IN & EX)
Service Limit: 0.1 mm
ENGINE
3-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsf650

Table of Contents