The safety labels shown above are affixed to your boiler. Although the labels are of high quality, they may become
dislodged or unreadable over time. Contact Harsco Industrial, Patterson-Kelley at 570.476.7261 or toll-free at
877.728.5351 for replacement labels.
2.5
S
P
AFETY
RECAUTIONS
Provide a suitable location for the boiler, away from normal personnel traffic, with adequate working space, adequate
clearances, proper ventilation and lighting, with a structure sufficiently strong and rigid to support the weight of the
boiler, all piping, and accessories.
2.5.1
Electrical Hazards
2.5.2
Burn, Fire, and Explosion Hazards
General Warning
WARNING
!
Improper use may
result in fire or injury.
Read instructions/safety
manual before installing,
operating or servicing boiler.
c
1998 HCS, Inc. 800-748-0241
Reorder No. 6020-V2WHPK
Burn hazard! Hot fluids. Use caution when servicing or draining boiler.
Hot Surface
Shock hazard! Properly lockout/tag out the electrical service and all other
energy sources before working on or near the boiler.
Shock hazard! Do not spray water directly on this boiler or on any electrical
components.
Electrical hazard! Do not alter wiring connections.
Burn, fire, and explosion hazards! Installation must be in strict conformance to all
applicable codes and standards including NFPA 54, ANSI Z223.1 and CAN/CSA
B.149. Install all required vent lines for gas devices. Refer to Section 3.6.
Hazard from incorrect fuels! Possible fire, explosion, overheating, and damage. Do
not use any fuels except the design fuels for the unit.
Over fire hazards! High pressure in gas supply could result in over firing of this or
other devices supplied from the same source.
Fire and explosion hazards! Close the main gas shutoff before servicing boiler.
Fire and explosion hazards! Do not store or use gasoline or other flammable vapors
or liquids in the vicinity of this or any other gas fired appliance.
Burn hazard! Possible hot surfaces. Do not touch gas vent during firing operation.
Use only factory recommended vent components.
Burn hazard! Pipes, vents, and boiler components could be hot. Do not touch piping
or stack surfaces during operation or immediately after shutdown of the boiler.
WARNING
!
Improper use may
result in fire or injury.
Read instructions/safety
manual before installing,
operating or servicing boiler.
c
1998 HCS, Inc. 800-748-0241
9
®
MACH
Gas Fired Boiler
Reorder No. 6020-V2WHPK

Advertisement