Hi I have a c750 Mach boiler my boiler always show check air pressure switch my inducer fan is running the holes is good what it can be the problem. Thank you
1 comments:
Mr. Anderson
May 19, 2025
If the Harsco Industrial MACH C750 boiler shows a "check air pressure switch" warning while the inducer fan is running and the holes are clear, possible problems include:
1. The air switch is not closing when the fan is running. 2. There may be an obstruction in the intake or exhaust ducts. 3. The burner may be dirty. 4. The blower may not be operating properly.
These should be checked and corrected before resetting the boiler.
® MACH C750-C1050 Outdoor Boilers Rev. 1.0 (11/17/2008) MACH GAS-FIRED BOILER ® C750 - C900 - C1050 OUTDOOR BOILER GUIDE This manual is to be used in conjunction with the MACH C750-C1050 Installation & Owner’s Manual. ® C.S.A Design-Certified Complies with ANSI Z21.13/CSA 4.9...
Kelley is not liable for errors appearing in this guide or for incidental or consequential Harsco Industrial, Patterson-Kelley makes no warranty, of any damages occurring in connection with the kind, with respect to this material, including, but not limited to...
These additional assemblies are listed in this manual and the ® MACH C750-C1050 Installation & Owner’s Manual. Be sure to identify your boiler and its specific installation requirements. It is essential to read, understand, and follow the recommendations of this manual before installing, operating, or servicing this equipment.
® ® See this MACH C750-C1050 Outdoor Boiler Manual & MACH C750-C1050 Installation & Owner’s Manual for additional information. Incorrect installation may result in severe injury or death. The boiler and these instructions is for outdoor use only. Do not install in any enclosure.
& seal tight connector ® See MACH C750-C1050 Installation & Owner’s Manual for specific electrical requirements and diagrams. Incorrect electrical connections may result in severe injury or death. NLET SSEMBLY See Drawing # BP00000218 Remove gas shut-off valve.
® See MACH C750-C1050 Installation & Owner’s Manual for additional venting requirements. The boiler vent should be installed per this manuals instruction. The information contained herein should be used as a guide only and is not intended to be used in lieu of qualified technical expertise.
Failure to comply may result in failure of venting system. This may cause severe injury or death. Use approved high temperature silicone between the adapter and exhaust connections. ® See MACH C750-C1050 Installation & Owner’s Manual for additional information. SSEMBLY See Drawing # BP00000218 Position exhaust pipe in center of hood gasket.
® MACH C750-C1050 Outdoor Boilers UPPORT Be sure to correctly support the hood using the hinged boiler cover as a prop engaging the angle supports inside the hood. Failure to do this could result in the hood falling and may cause severe injury or death.
® MACH C750-C1050 Outdoor Boilers Maintenance ® ® The MACH outdoor boiler requires maintenance as described in MACH Installation & Owner’s Manual (latest edition) as well as the additional maintenance listed below. General Warning These additional maintenance items should be performed monthly.
Need help?
Do you have a question about the MACH C750 and is the answer not in the manual?
Questions and answers
Hi I have a c750 Mach boiler my boiler always show check air pressure switch my inducer fan is running the holes is good what it can be the problem. Thank you
If the Harsco Industrial MACH C750 boiler shows a "check air pressure switch" warning while the inducer fan is running and the holes are clear, possible problems include:
1. The air switch is not closing when the fan is running.
2. There may be an obstruction in the intake or exhaust ducts.
3. The burner may be dirty.
4. The blower may not be operating properly.
These should be checked and corrected before resetting the boiler.
This answer is automatically generated