1 INTRODUCTION

This manual describes the installation and operation of MACH
BTUH. Natural gas, propane, and dual fuel (natural and propane) units are described. It also includes 208/3/60,
240/3/60, or 480/3/60 voltages for the 3 and 4 million BTUH input boilers. This manual describes the natural gas
design. Information for operation with other fuels is included in the various sections of this manual as applicable. If
you have any questions on the information contained within, or do not fully and completely understand the content,
please contact Harsco Industrial, Patterson-Kelley Technical Service at 570.476.7261 or toll free at 877.728.5351.
®
The MACH
C1500H/C2000H/C2500/C3000/C4000 gas fired boilers are fully modulating using variable speed
combustion blowers, sophisticated microprocessor controls, modulating gas safety shut off / control valves and a
unique aluminum alloy heat exchanger capable of operating in a fully condensing mode to provide maximum
efficiency in a minimum amount of space. The high quality materials and thoroughly tested design of the boiler should
provide years of trouble free service if the instructions in this manual are followed carefully.
This manual covers the installation of MACH
fuel (natural gas and propane) boilers. The model number may be followed by a prefix or suffix letter in some cases to
indicate special features or different options.
While details may differ slightly, basic operation is the same for all models. Check the rating plate for correct fuel
usage and gas pressures.
The boiler is only a part of the complete heating system. This boiler may be fully operational and yet because of poor
circulation, control, or other operating characteristics not deliver heat to the desired location. Additional equipment
such as temperature sensors, pumps, flow switches, balancing valves, and check valves will be required for
satisfactory operation of any system. Harsco Industrial, Patterson-Kelley cannot be responsible for the design or
operation of such systems and a qualified engineer or contractor must be consulted.
2

SAFETY

2.1
G
ENERAL
®
The MACH
C1500H/C2000H/C2500/C3000/C4000 gas fired boilers must be:
Installed, operated, and serviced in accordance with instructions contained in this manual and other supplemental
manuals.
Installed by qualified personnel in accordance with designs prepared by qualified facility engineers including:
structural, mechanical, electrical, and other applicable disciplines.
Operated and serviced in accordance with a comprehensive safety program determined and established by the
customer. Do not attempt to operate or service until such a program has been established.
Operated and serviced by experienced, qualified, and properly trained personnel in accordance with all applicable
codes, laws, and regulations.
NOTICE! Each safety device must be maintained and checked per the recommended schedule. Refer to Section
5.1 of this manual.
®
boilers with inputs from 1.5 million through 4 million
®
C1500H/C2000H/C2500/C3000/C4000 natural gas, propane, and dual
7
®
MACH
Gas Fired Boiler