Alarm (Ch8); Communication (Ch9); Pfb (Ch10) - Fuji Electric PXG5 Instruction Manual

Micro controller x
Hide thumbs Also See for PXG5:
Table of Contents

Advertisement

Parameter
Parameter
Function
display symbol
name
di1
"
" (di1)
DI-1 function
Sets the
selection
function of
DI-1
"
di5
" (di5)
DI-5 function
Sets the
selection
function of
DI-5
do1t
"
" (do1T)
Sets the DO1
Sets the
output event
function of
type
DO1
doP1
"
" (doP1)
Sets DO1
Assigns the
option function
four types of
option
functions in
bit units
"
do5t
" (do5T)
Sets the DO5
Sets the
output event
function of
type
DO5
doP5
"
" (doP5)
Sets DO5
Assigns the
option function
four types of
option
functions in
bit units
"
rmP
" (rMP)
ramp SV
Sets the
ON/OFF
ramp SV
ON/OFF
"
rmPL
" (rMPL)
Ramp SV-
Sets the slope
Decline
for a falling SV
during ramp
SV operations
"
rmPh
" (rMPH)
Ramp SV-
Sets the slope
Incline
for a rising SV
during ramp
SV operations
"
rmPU
" (rMPU)
Ramp SV-
Sets the unit
slope units of
of time for the
time
slope during
ramp SV
operations
Svt
"
" (SvT)
Ramp SV - SV
Displays the
display mode
SV during
selection
ramp
operations or
the SV goal
value on the
SV display
[trL
"
" (CTrL)
Control
Allows you to
methods
select the
control
method.
Initial
Setting range
value
0 (No function)
0
1 (Switchover between STBY ON/OFF)
2 (Switchover between Auto/Manual)
3 (Switchover between Local/Remote)
4 (No function)
5 (No function)
6 (Start AT (standard))
7 (Start AT (low PV))
8 (No function)
9 (No function)
10 (Ramp SV ON/OFF)
11 (Ramp SV HOLD)
12 (Ramp soak OFF)
13 (Ramp soak RUN/HOLD)
14 (No function)
15 (Latch release (all))
16 (Latch release (DO1))
17 (Latch release (DO2))
18 (Latch release (DO3))
19 (Latch release (DO4))
20 (Latch release (DO5))
21 (Start timer (DO1))
22 (Start timer (DO2))
23 (Start timer (DO3))
24 (Start timer (DO4))
25 (Start timer (DO5))
26 (SV No. + 1)
27 (SV No. + 2)
28 (SV No. + 4)
29 (PID No. + 1)
30 (PID No. + 2)
31 (PID No. + 4)
32 (No function)
33 (No function)
34 (No function)
35 (SV No.+1, PID No.+1)
36 (SV No.+2, PID No.+2)
37 (SV No.+4, PID No.+4)
38 (Pattern No.+1)
39 (Pattern No.+2)
40 (Pattern No.+4)
41 (Soft start)
42 (Ramp soak RUN)
43 (Ramp soak HOLD)
44 (Ramp soak RUN at DO1 startup)
45 (Ramp soak RUN at DO2 startup)
46 (Ramp soak RUN at DO3 startup)
47 (Ramp soak RUN at DO4 startup)
48 (Ramp soak RUN at DO5 startup)
0 to 48
0
0 to 102
0
0000 to 1111
0000
bit0 : output latch function
bit1 : error alarm function
bit2 : non-excitation output
alarm function
bit3 : hold reset function
0 to 102
0
0000 to 1111
0000
bit0 : output latch function
bit1 : error alarm function
bit2 : non-excitation
output alarm function
bit3 : hold reset function
oFF (ramp SV OFF)
on
on (ramp SV ON)
0 to 100% FS
0°C
0 to 100% FS
0°C
hoUr (slope temperature/hour)
hoUr
Min (slope temperature/min)
rMP (SV during ramp)
rMP
TrG (target SV)
Pid (PID control)
Pid
FUZY (Fuzzy PID control)
SELF (Self-tuning control)
Pid2 (PID2 control)
Parameter
Parameter
Remarks
display symbol
name
PrCS
(Note11)
"
" (PrCS)
Control target
RST
Stmd
"
" (STMd)
Start mode
6-8

Alarm (Ch8)

Sets the detect conditions for each type of alarm.
Parameter
Parameter name
display symbol
"
A1hY
" (A1hy)
ALM1 hysteresis
"
dLY1
" (dLY1)
ALM1 delay
dL1U
"
" (dL1U)
ALM1 delay time
units
A5hY
"
" (A5hy)
ALM5 hysteresis
"
dLY5
" (dLY5)
ALM5 delay
"
dL5U
" (dL5U)
ALM5 delay time
units
hb1
"
" (hb1)
HB alarm set value
for CT
"
hb1h
" (hb1h)
HB alarm
hysteresis for CT
"hS1"
Load short-circuit
alarm setting value
for CT
"hS1h"
Load short-circuit
alarm hysteresis
for CT
"
lbTm
" (LbTM)
Loop break
(Note3)
detection time
RST
"
LbAb
" (LbAb)
Loop break
detection range
(°C)
6-9

Communication (Ch9)

Sets the communication conditions towards the host computer.
Parameter
Parameter name
display symbol
"
Stno
" (Stno)
ST No. setting
CoM
"
" (CoM)
baud rate/parity
setting
S[[
"
" (SCC)
Communication
permissions

PFB (Ch10)

6-10
Changes settings to use valve control.
Parameter
Parameter name
display symbol
PGAP
"
" (PGAP)
PFB dead band
"
trvL
" (TrvL)
Valve stroke time
[AL
"
" (CAL)
PFB input
adjustment
command
Sections
5-1 to
5-8
(Note19)
RST
– 9 –
Function
Setting range
Allows you to
SRV1 (Servo control 1)
select the
SRV2 (Servo control 2)
control target.
PFB (Position feedback
control)
Sets the
Auto (auto mode startup)
operation
Man (manual mode startup)
mode when
Rem (remote mode startup)
starting up
STby (standby make startup)
Function
Setting range
Sets the hysteresis
0 to 50% FS
for alarm output 1
ON/OFF
Sets the delay
0 to 9999 [sec/min] 0(sec/
before detecting
alarm output 1
Sets the delay time
sec (second)
units for alarm
Min (minute)
output 1
Sets the hysteresis
0 to 50% FS
for alarm output 3
ON/OFF
Sets the delay
0 to 9999 [sec/min]
detecting for alarm
output 3
Sets the delay time
sec (second)
units for alarm
Min (minute)
output 3
Sets the heater
0.0 to 50.0A
burnout alarm
detection value for
CT
Sets the heater
0.0 to 50.0A
burnout alarm ON/
OFF hysteresis for
CT
Sets the heater
0.0 to 50.0A
load short-circuit
alarm setting value
for CT.
Sets the heater
0.0 to 50.0A
load short-circuit
alarm ON/OFF
hysteresis for CT.
Sets the time
0 to 9999 sec
before detecting a
broken loop
Sets the
0 to 100% FS
temperature range
before detecting a
broken loop
Function
Setting range
Sets the station
0 to 255 (0:
number.
unresponsive
communication)
Sets the baud
96od (9600 bps/odd)
rate and parity
96Ev (9600 bps/even)
check
96no (9600 bps/none)
19od (19200 bps/odd)
19Ev (19200 bps/even)
19no (19200 bps/none)
Sets whether or
r (read only permission)
not overwriting is
rW (read and overwrite
possible from the
permission)
master side (PC,
etc.)
Function
Setting range
Sets the PFB dead
0.0 to 100.0%
band
Sets the full stroke
5 to 180 sec
time for the valve
Adjusts the zero/
0 (none/forcibly termination)
span for PFB input
1 (zero adjustment)
2 (span adjustment)
3 (automatic adjustment)
Initial
Remarks
value
PFb/
(Note16)
Srv1
RST
(with
PFB/
without
PFB)
AUTo
Initial
Remarks
value
1°C
(Note3)
min)
sec
1°C
0(sec/
min)
sec
0.0A
(Note10)
(Note13)
0,5A
(Note10)
(Note13)
0.0A
(Note10)
(Note13)
0.5A
(Note10)
(Note13)
0 sec
10°C
Initial
Remarks
value
1
(Note17)
96od
(Note17)
RST
rW
(Note17)
Initial
Remarks
value
5%
(Note16)
30 sec
(Note16)
-
(Note8)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxg9Micro controller x pxg5Micro controller x pxg9

Table of Contents