Password Setup (Ch11)

6-11
Sets the password. Passwords can be set at three levels.
Display
Parameter name
Function
"
PAS1
" (PAS1)
Password1 setup
Sets password 1.
"
PAS2
" (PAS2)
Password2 setup
Sets password 2.
"
PAS3
" (PAS3)
Password3 setup
Sets password 3.

Display (Ch12)

6-12
Sets the parameter mask function Optional parameters can be set not to display.
For details on the parameter mask function, refer to the "Operation Manual".
Display
Parameter name
Function
dP01
"
" (dP01)
Parameter mask of
Sets the
each parameter
parameters to be
displayed/not
displayed.
"
dP30
" (dP30)
Parameter mask of
Sets the
each parameter
parameters to be
displayed/not
displayed.
Note 1: Displayed when the seventh digit of the model code is H, K, F , 2 or E, or the eleventh
digit is D.
Note 2: Displayed when the ninth digit of the model code is not 0, or the
eleventh digit is C.
Note 3: Display changes according to the DO number and the selected alarm type.
Note 4: Displayed when the fifth digit of the model code is not V or S and the sixth digit is A,
C, E or P.
Note 5: "
SvL
" and "
Svh
" must be set so that SvL < Svh.
When the setting values of "
("
Sv1 Ch3
") through SV setting value 7 ("
Note 6: Set the same value as the one for the Normal/Reverse setting ("
Note 7: Displayed when the fifth digit of the model code is A or C.
Note 8: Displayed when the fifth digit of the model code is V.
Note 9: Displayed when the fifth digit of the model code is E or P .
Note 10: Displayed when the seventh digit of the model code is G or J, or when the eleventh
digit is A.
Note 11: The number of parameters to be displayed varies depending on the number of DIs
that PXG has.
For more details on "41: DI soft start", refer to the "Operation Manual".
Note 12: Displayed when the sixth digit of the model code is R or S.
Note 13: The parameter uses this even if the terminal uses CT2 input.
Note 14: Select the proper setup range for the output type.
Note 15: Do not set 4 to 7.
Note 16: Displayed when the fifth digit of the model code is V or S.
Note 17: Displayed when the seventh digit of the model code is M, V, K, J, F or U.
Note 18: Displayed when the sixth digit of the model code is E or P .
Note 19: When the fifth digit of the model code is S or V, be sure to select PID control. Options
other than PID control cannot be used.
Note 20: When changing the SV with the front key, do not change the "
communication.Otherwise, the changed SV may not be stored correctly.
Note 21: Do not change this parameter during the ramp soak operation.
Be sure to set "
PrG
" = "
oFF
" before changing the parameter.
7

Functions

This controller has five types of temperature control functions and three types of valve control
functions. Select according to type and use.
The ramp soak function (
Caution
SV selection function (
Temperature Control Functions
ON/OFF (2-position)
Turns the control output ON/OFF according to the size
control
relationship of PV and SV Can build a control system
out of simple elements such as SSR. Suitable when
accuracy is not requested.
PID Controls
PID calculation and controls proceed according to the
previously set PID parameters.
PID parameters can be set manually or through auto-
tuning (AT).
It is the most basic control in this equipment.
Fuzzy PID Control
PID control with function that reduces the amount of
overshoot during control. It is effective when you want
to suppress overshoot when SV is changed, even if you
may take a long time to reach the target value.
Self-tuning Control
Automatically calculating PID control according to the
control target or SV change. It is effective when the
control conditions change frequently.
PID2 Control
In case which the power supply of the control target
goes ON → OFF → ON, this PID2 control can suppress
the amount of overshoot during control target turns OFF
→ ON.
Setting range
0000 to FFFF
0000 to FFFF
0000 to FFFF
Setting range
0000 to FFFF
0000 to FFFF
SvL
" and "
Svh
" are changed, check SV setting value 1
Sv7 Ch3
").
rEv Ch2
Svn
page 12), remote SV function (
page 15), and
page 16) cannot be combined.
Valve Control Functions
Servo Control 1
(Servo 1)
Servo Control 2
Initial
(Servo 2)
Remarks
value
0000
0000
Position Feedback
0000
(PFB Control)
7-1
Initial
Remarks
value
Acts as an ON/OFF control when the PID parameter is set to "
Value
ON/OFF control switches the control output to ON (100%) or OFF (0%) according to the size rela-
different
tionship of PV and SV.The output hysteresis can be set under the parameter "
depending
on the
model
Reverse Operation (heat control)
code
Method used to control the electrical heating furnace."Set the
Value
according to the control target.
different
depending
Parameter
on the
P
"
"
model
code
rEv
"
hYS
"
"
Normal Operation (cooling control)
Method used to control the cooling machine.
Parameter
").
"
P
"
rEv
"
hYS
"
"
Point
7-2
" parameter via
PID controls run as long as the parameter is set to "
CH 7
"). The PID controls calculate PID based on the set values for parameters "
"
Ar
", and output the calculated result (-3% to 103%).
Each parameter can be set either by manually tuning the values or by running auto-tuning (AT)
to automatically set the values.
Refer to
For more details on auto-tuning, see "7-6 Auto-tuning" (page 11)
Setting PID Control
Display the system menu ("
1
Display the control parameter ("
2
Press the
7-1
3
(page 10)
7-3
7-2
(page 10)
Related to normal PID controls, fuzzy PID control acts with small overshoot.
You will need to run auto-tuning to set the PID parameter when using fuzzy control.
7-3
(page 10)
Setting fuzzy PID control
Display the system menu ("
7-4
1
(page 11)
Display the controller parameter ("
2
7-5
(page 11)
Press the
3
Refer to
For more details on auto-tuning, see "7-6 Auto-tuning" (page 11)
– 10 –
Regulates the valve position according to [OPEN] and
[CLOSE] of the contact output.
Regulates the valve position according to [OPEN] and
[CLOSE] of the contact output.It can also display the
valve ís degree of openness according to the position
position signal from the valve. However, it cannot be
used to calculate the control output.
Controls the valve according to a calculation performed
on the opening signal.Regulates the valve position
according to [OPEN] and [CLOSE] of the contact
output.
It can be used when there is an opening signal coming
from the valve.

ON/OFF (2-position) Control

process value
Set Value
0.0
rv--
arbitary (factory
setting: 1 °C)
control output
process value
Set Value
0.0
no--
arbitary (factory
setting: 1 °C)
control output
During ON/OFF control, the I and D settings do not affect control.
The manual operation during ON/OFF control will become MV=100%
when the
key is pressed, and MV=0% when the
If the hysteresis width is narrow, and PV and SV are nearly equal, the
output may frequently switch ON and OFF. Note that it may affect the
operation life of the contact output.
PID Controls
" ≠ 0.0 ("
P
SYS Ch 7
").
CTrL
") and choose PID controls ("
key to set the value.
Fuzzy PID Control
").
SYS [h 7
[trL
") and choose fuzzy ("
key to set the value.
7-7
(page 11)
7-7
(page 11)
7-8
(page 12)
" = 0.0 ("
").
P
Pid Ch 2
hYS
" ("
Pid Ch 2
").
hYS
" to an appropriate value
PV
HYS
SV
t
PV<SV
ON
PV>SV
OFF
PV
HYS
SV
t
PV>SV
ON
PV<SV
OFF
key is pressed.
Pid Ch 2
") and "
CTrL
" = PID ("
SYS
P
", "
i
", "
d
", and
Pid
").
FUZY
").

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxg9Micro controller x pxg5Micro controller x pxg9

Table of Contents