Functions and operations

Various mode setup and adjustment of KP-FD500GV/F500GV/FD202GV/F202GV/FD145GV/F145GV/FD140GV/F140GV
/FD83GV/F83GV/FD33GV/F33GV are performed by the remote control via Gigabit Ethernet. Operation and adjustment way
of function utilized are described below.
Each command is classified into following 5 types:
Enumeration
Integer
Float
Command
String
"Standard" means the function based on GENiCAM
original function. The function with description of "related to SELECTOR" is affected to change of SELECTOR value.
The software for GENiCAM
value to address directly.
1. Commands for acquisition
(1) ACQUITION : Setting for image acquisition method
・MODE : Select of mode
Command name
Address
Values (Factory setting 1) : 1 "Continuous" Frames are captured continuously until stopped with the STOP command.
・START : Acquisition start
Command name
Address
Values (write only)
・STOP : Acquisition stop
Command name
Address
Values (write only)
・EXTRA MODE : Special one shot
Command name
Address
Values (Factory setting 0) : 0 "Off"
Exposure
(Internal sync)
START
Data output
Exposure
START command
Data output
: Command dealing with enumeration-type parameter
: Command dealing with integer-type parameter
: Command dealing with float-type parameter
: Executable format command
: Command dealing with string
TM
TM
can operate by using command name. Moreover, it can also be operated by reading /writing the
: AcquitionMode (Enumeration / Standard)
: A0030000 h
2 "MultiFrame" The number of frames specified by FRAME COUNT is captured.
3 "SingleFrame" One frame is captured.
: AcquiationStart (Command / Standard)
: A0030004 h
: 1
Start the acquisition of the camera image.
: AcquitionStop (Command / Standard)
: A0030008 h
: 0
Stop the acquisition of he camera image.
*using when MODE is SingleFrame
: AcquitionModeExtra (Enumeration / Custom)
: A0F30018 h
The camera releases the shutter according to internal synchronization.
1 "On"
The camera releases the shutter when START command is received.
Data output timing when EXTRA MODE is Off
Data output timing when EXTRA MODE is On
Standard Feature Naming Convention (SFNC) and "Custom" means the